Line Topology Estimation of Indoor power Lines Using Multipoint Single Ended Loop Testing

نویسندگان

  • S. Ravishankar
  • M. Bharathi
چکیده

Quality of broadband connectivity over a residential power line is dependent on its topology; which is very different from twisted pair copper used in telephony. In this paper methods to estimate the topology of a power line are investigated. A two step procedure comprising of a set of correlation time domain Reflectometry (CTDR) measurements based on Single Ended Loop Testing (SELT) and an initial topology estimate as a first step, followed by a comparison with frequency domain Reflectometry (FDR) measurement as a second step to finally ascertain the power line topology. A set of codes with complementary autocorrelation property is used for probing the line. The number of bridge taps (BTs) in a power line is large and spaced closely; hence multiple applications of CTDR from different sockets are carried out to understand tap positions close to the measuring socket. An analysis of the measurements from multiple CTDR applications is then used to generate a first estimate of the complete power line topology. In the second step a FDR signature of the loop is computed and compared with the frequency domain Reflectometry (FDR) measurement in a mean squared sense to validate the findings. The CTDR and FDR use existing functional blocks of any DSL modem and do not need any additional equipment for measurement. This method is tested for a wide range of power line topologies with multiple bridge taps. The transfer characteristic of the estimated power line loop topology is derived using transmission matrix method and the channel capacity estimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the estimation of the loop topology with SELT

Telecom operators base their DSL-tariffs mainly on the offered bit rate. The maximal achievable bit rate is different for each customer, because it depends on two parameters. On the one hand, the transfer function of the ‘subscriber loop’, which depends on the network topology (the cabling between the central office and the subscriber) and on the other hand the Power Spectral Density of the noi...

متن کامل

Single-ended Line Testing - a White Box Approach

A measurement, modelling and identification system is proposed to qualify a subscriber line with the constraint that only measurements can be conducted at the Central Office. The system uses the one-port scattering parameter as a base measurement of the loop. The time domain version of this scattering parameter will be pre-processed so that the features, which are the start, maximum and end pos...

متن کامل

Single Ended Loop Topology Estimation using FDR and Correlation TDR in a DSL Modem

The broadband capability of a DSL is dependant on the copper access network. Single Ended Loop Testing (SELT) is the most preferred and economical way in estimating the copper loop topology. The combined use of complementary code based Correlation Time Domain Reflectometry (CTDR) and Frequency Domain Reflectometry (FDR) for accurate loop topology estimation is presented in this paper. The advan...

متن کامل

Feasibility and problems of DSL loop topology identification via single-ended line tests

Abstrac t Digital subscriber lines (DSL) offer the possibility to deliver broadband services over the existing telephone network. Yet, before deploying DSL, the subscriber loops must be tested to see whether they can support high-speed data services, and at what rate. Single-ended automatic qualification is essential for achieving low-cost deployment of DSL, since it allows loops to be qualifie...

متن کامل

Loop Identification and Capacity Estimation of Digital Subscriber Lines with Single Ended Line Testing

Digital subscriber lines offer the possibility to deliver broadband services over the existing telephone network. Still, beforehand subscriber loops must be tested to see whether they can support high-speed data services, and at what bit rate. From the existing measurement techniques, Single Ended Line Testing is often preferred because all necessary measurements can be performed from the centr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012