A case of isolated bicuspid pulmonary valve
نویسندگان
چکیده
We present a 73 years old woman who presented with pelvic cancer, ongoing sepsis and presumably a new diastolic murmur. Her transthoracic echocardiogram, as part of a sepsis screen, showed an abnormal pulmonary valve with moderate regurgitation. Trans-oesophageal echocardiography using 3D imaging showed a bicuspid pulmonary valve as the cause for the moderate regurgitation, but with no clear source of infection. Bicuspid pulmonary valve as an isolated clinical entity is a rare finding in clinical practice. Bicuspid pulmonary valves tend to be more commonly associated with other congenital cardiac anomalies. Whereas, the incidence of bicuspid aortic valve is estimated to be about 1-2%, the incidence of bicuspid pulmonary valve is thought to be much lower at around 0.1%. This could be an underestimate due to difficulty in visualising the pulmonary valve en-face on standard two-dimensional echocardiography. The true prevalence of the condition may be uncovered by the routine use of 3D echocardiography.
منابع مشابه
Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملMultimodality imaging of isolated bicuspid pulmonary valve leading to pulmonary stenosis
Isolated bicuspid pulmonary valve is a rare arterial valve anomaly with very few reports in the literature. It is usually in association with other congenital cardiac lesions. However, the true incidence of bicuspid pulmonary valve could be underestimated because of the difficulty in imaging pulmonary valve morphology with conventional two-dimensional transthoracic echocardiography. A 21-year-o...
متن کاملInvestigation of an anatomically variant isolated bicuspid pulmonary valve: A case report: Erratum
INTRODUCTION We provide a discussion of the anatomical characteristics of the bicuspid pulmonary valve (BPV) in this paper. We performed an autopsy of an isolated BPV found in the heart of a deceased individual. The deceased was a man in his 60s and had no previous history of cardiovascular disease. The heart weighed 260 g and had mild right ventricular hypertrophy. The pulmonary valve had a fi...
متن کاملAbnormal Haemodynamic Flow Patterns in Bicuspid Pulmonary Valve Disease
Abnormal flow patterns in the aortas of those with bicuspid aortic valves (BAVs) are increasingly recognized as important in the pathogenesis of aortic dilatation but pulmonary flow patterns in bicuspid pulmonary valves have not been studied. Bicuspid pulmonary valve disease is rare and a small numbers of case reports describe concomitant pulmonary artery dilation similar to the dilation of the...
متن کاملBicuspid aortic and pulmonary valves complicated by acute aortic dissection in a highly trained athlete – Case report and review of the literature
Acute aortic dissection is typically seen in the middle aged and elderly population, the majority of the cases are related to systemic hypertension and atherogenic process. In contrast, aortic dissection-related deaths in the young are rare and are mainly associated with genetically based disorders and congenital cardiac anomalies. One of the most recognized congenital risk factors that predisp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -