Accuracy of Intensity and Inclinometer Output of Three Activity Monitors for Identification of Sedentary Behavior and Light-Intensity Activity

نویسندگان

  • Lucas J. Carr
  • Matthew T. Mahar
چکیده

Purpose. To examine the accuracy of intensity and inclinometer output of three physical activity monitors during various sedentary and light-intensity activities. Methods. Thirty-six participants wore three physical activity monitors (ActiGraph GT1M, ActiGraph GT3X+, and StepWatch) while completing sedentary (lying, sitting watching television, sitting using computer, and standing still) light (walking 1.0 mph, pedaling 7.0 mph, pedaling 15.0 mph) intensity activities under controlled settings. Accuracy for correctly categorizing intensity was assessed for each monitor and threshold. Accuracy of the GT3X+ inclinometer function (GT3X+Incl) for correctly identifying anatomical position was also assessed. Percentage agreement between direct observation and the monitor recorded time spent in sedentary behavior and light intensity was examined. Results. All monitors using all thresholds accurately identified over 80% of sedentary behaviors and 60% of light-intensity walking time based on intensity output. The StepWatch was the most accurate in detecting pedaling time but unable to detect pedal workload. The GT3X+Incl accurately identified anatomical position during 70% of all activities but demonstrated limitations in discriminating between activities of differing intensity. Conclusions. Our findings suggest that all three monitors accurately measure most sedentary and light-intensity activities although choice of monitors should be based on study-specific needs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of ascorbic acid on physiological and biochemical responses of Zinnia elegans L. to different levels of light intensity

The aim of this study was to investigate the effect of different light intensities and ascorbic acid on some physiological and biochemical characteristics of Zinnia elegans L. The experiment was designed as a completely randomized design in a form of split-plot with three replications. The treatments were consisted of three light intensity levels (600, 1200 and 1800 μmol m-2 s-1) as the main fa...

متن کامل

Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitors

BACKGROUND Health is associated with amount of daily physical activity. Recently, the identification of sedentary time as an independent factor, has gained interest. A valid and easy to use activity monitor is needed to objectively investigate the relationship between physical activity, sedentary time and health. We compared validity and reproducibility of physical activity measurement and post...

متن کامل

Effect of one or two sessions per day of physical activity, with equal intensity and duration, on adiponectin and insulin resistance in sedentary middle-aged men

improves insulin resistance. However, the effect of training sessions a day is not clear in this regard. The aim of this study was to investigate the effect of one or two sessions a day of exercise training, with equal intensity and duration, on insulin resistance in sedentary middle-aged men. Materials & Methods: 30 sedentary middle-aged male volunteers (age=43.6±6.5 yr, weight=80.4±13.6kg...

متن کامل

Evaluation of the Effect of Protective Sleeve on Output Intensity of Light Emitting Diode Light Cure Units

Aim: The purpose of this study was to compare the difference in the output intensity of Light Emitting Diode (LED) light cure (LC) devices with and without a protective sleeve and its clinical significance.  Materials and Methods: The output intensity of 152 LC units in dental offices across the state of Odisha were examined. The collection of related information included an average number of e...

متن کامل

SenseWearMini and Actigraph GT3X Accelerometer Classification of Observed Sedentary and Light-Intensity Physical Activities in a Laboratory Setting

Purpose: To compare the ability of SenseWear Mini (SWm) and Actigraph GT3X (AG3) accelerometers to differentiate between healthy adults' observed sedentary and light activities in a laboratory setting. Methods: The 22 participants (15 women, 7 men), ages 19 to 72 years, wore SWm and AG3 monitors and performed five sedentary and four light activities for 5 minutes each while observed in a labora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012