Radiobiologically based treatment plan evaluation for prostate seed implants
نویسندگان
چکیده
PURPOSE Accurate prostate low dose-rate brachytherapy treatment plan evaluation is important for future care decisions. Presently, an evaluation is based on dosimetric quantifiers for the tumor and organs at risk. However, these do not account for effects of varying dose-rate, tumor repopulation and other biological effects. In this work, incorporation of the biological response is used to obtain more clinically relevant treatment plan evaluation. MATERIAL AND METHODS Eleven patients were evaluated. Each patient received a 145 Gy implant. Iodine-125 seeds were used and the treatment plans were created on the Prowess system. Based on CT images the post-implant plan was created. In the post-plan, the tumor, urethra, bladder and rectum were contoured. The biologically effective dose was used to determine the tumor control probability and the normal tissue complication probabilities for the urethra, bladder, rectum and surrounding tissue. RESULTS The average tumor control probability and complication probabilities for the urethra, bladder, rectum and surrounding tissue were 99%, 29%, 0%, 12% and 6%, respectively. These measures provide a simpler means for evaluation and since they include radiobiological factors, they provide more reliable estimation of the treatment outcome. CONCLUSIONS The goal of this work was to create more clinically relevant prostate seed-implant evaluation by incorporating radiobiological measures. This resulted in a simpler descriptor of treatment plan quality and was consistent with patient outcomes.
منابع مشابه
SU-E-T-458: Radiobiological Comparison of Single and Dual-Isotope Prostate Seed Implants.
PURPOSE Several isotopes are available for low dose-rate brachytherapy of the prostate. Currently, most implants use a single isotope. However, the use of dual-isotope implants may yield an advantageous combination of characteristics such as half-life and relative biological effectiveness. However, the use of dual-isotope implants complicates treatment planning and quality assurance. Do the ben...
متن کاملIntensity Modulated Proton Therapy as a Boost Treatment after Prostate Seed Implant: A Treatment Planning Study
Purpose: Combination of Prostate Seed Implant (PSI) with External Beam Radiation Therapy (EBRT) remains as an attractive option for patients with intermediate or high-risk prostate cancer. One of the most widely used approaches is to use external beam radiation therapy (EBRT) to deliver boost doses after permanent prostate seed implant (PSI). In this study, the feasibility of using Intensity Mo...
متن کاملThree-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کاملEvaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy
PURPOSE To analyze the seed loss and displacement and their dosimetric impact in prostate low-dose-rate (LDR) brachytherapy while utilizing the combination of loose and stranded seeds. MATERIAL AND METHODS Two hundred and seventeen prostate cancer patients have been treated with LDR brachytherapy. Loose seeds were implanted in the prostate center and stranded seeds in the periphery of the gla...
متن کاملThree-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some ssues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calcula on in order to achieve an accurate dose delivery. Dose verifica on in complex radia on therapy techniques, such as intensity‐modulated radia on therapy (IMRT) calls for volumetric, ssue equivalent and energy independent dosimeter. The purpose of this study i...
متن کامل