High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.
نویسندگان
چکیده
PURPOSE To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. MATERIALS AND METHODS High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). RESULTS In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P < 0.0001). Coronary wall thicknesses (± standard deviation [SD]) were not significantly different: 1.10 ± 0.14 mm (3D spiral (2RR)), 1.20 ± 0.16 mm (3D spiral (1RR)), 1.14 ± 0.15 mm (2D spiral), and 1.21 ± 0.17 mm (TSE). Wall thickness reproducibility ranged from good (ICC = 0.65, 3D spiral (1RR)) to excellent (ICC = 0.87, 3D spiral (2RR)). CONCLUSION High-resolution 3D spiral imaging with B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression.
منابع مشابه
High resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging
Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...
متن کاملReproducibility of coronary vessel wall imaging techniques
Background Coronary wall thickness measurements must be highly reproducible to be useful in longitudinal studies. While 2D turbo-spin-echo (TSE) and spiral techniques are commonly used, 3D techniques reduce partial-volume effects and allow greater vessel coverage. Recently, 3D coronary wall imaging was demonstrated with 100% respiratory efficiency (RE) using beat-to-beat respiratory motion corr...
متن کاملHigh resolution, free-breathing coronary artery imaging with >99% respiratory efficiency: comparing beat to beat respiratory motion correction with navigator gating
Introduction: High-resolution coronary artery imaging is commonly gated to end-expiration using diaphragmatic navigator echoes, resulting in inherently low respiratory efficiency (RE) which is further exacerbated by respiratory drift. Recently, it was demonstrated that epicardial fat can be used as a marker of coronary artery position in a 3D beat-to-beat non-model based subject-specific respir...
متن کاملSelf-Gated Free Breathing 3D Coronary Cine Imaging With Enhanced Artery Contrast by Exploiting the Simultaneously obtained Water and Fat Visualization
INTRODUCTION In this work, a respiratory and cardiac self-gated free-breathing 3D cine SSFP imaging technique is proposed utilizing multiple echo acquisitions to separate water and fat for optimal visualization of the coronary arteries. Multi-echo hybrid radial sampling has been shown to have a high data acquisition efficiency and a high robustness to motion. By frequently acquiring the k-space...
متن کاملComparison of respiratory navigator techniques for interleaved high-resolution coronary vessel wall imaging
Background Three-dimensional high-resolution PSIR LGE [1], flowindependent vessel wall imaging [2], or T1 mapping [3] are all implemented with interleaved sequences, where the same volume is imaged multiple times with different inherent contrast. These volumes are then processed together to generate additional information, e.g. recovering the sign of magnetization, depicting vessel walls via su...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2011