Falsely Low Results Obtained with the Hybrltech Tandem # { 174 } - R

نویسندگان

  • Henrik Alfthan
  • Giuseppe Banfi
  • Michelangelo Murone
چکیده

Prostate-specific antigen (PSA) is a recently described marker for prostate carcinoma (1). In patients with prostatic cancer the concentration of PSA in serum can be as much as 10 mg/L, whereas concentrations in healthy men are <2.8 zg/L (2). Hybritech’s immunoradiometric assay for PSA has been in routine use in our laboratory for 15 months. Its reproducibility is generally good, but two samples with values of 48 and 38 p.g/L showed abnormal variation between duplicates. We re-assayed these samples diluted 10to 1000-fold, and found that their PSA concentrations actually were 8.60 and 8.90 mg/L, respectively. This suggested that a “hook effect”-i.e., a decreased response in samples containing a large excess of antigen-had caused a falsely low result. The hook effect is a phenomenon usually associated with one-step “sandwich”-type assays (3). Therefore, we modified the PSA assay to a two-step assay with 16+2 h incubation. Surprisingly, an identical hook effect was also observed in this procedure. Fractionation of the samples by gel chromatography (Sephacryl S-200) showed that the main PSA activity was eluted in a volume corresponding to a molecular mass of -30 kDa, which corresponds to that of PSA (1). A smaller 16-kDa PSA species contributed -9% of the total PSA activity. When we assayed these components at various dilutions, the dilution curves were parallel. A large difference in affinity for the solid-phase antibody of either of these components could have explained the hook effect. Another potential cause, heterogeneity of the solid-phase antibody (3), is unlikely, because both antibodies used in the assay were monoclonal. Since detecting falsely low results in the first two patients, we assayed 320 samples at two dilutions and found four more samples with true values of -3.00 mg/L that, undiluted, gave falsely low results of -400 g/L. This problem has to be considered when the PSA assay is used to monitor patients with prostatic cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Falsely Low Results Obtained with the Hybrltech Tandem # { 174

Prostate-specific antigen (PSA) is a recently described marker for prostate carcinoma (1). In patients with prostatic cancer the concentration of PSA in serum can be as much as 10 mg/L, whereas concentrations in healthy men are <2.8 zg/L (2). Hybritech’s immunoradiometric assay for PSA has been in routine use in our laboratory for 15 months. Its reproducibility is generally good, but two sample...

متن کامل

Numerical simulation of nanofluid flow over diamond-shaped elements in tandem in laminar and turbulent flow

In this paper, the Al2O3-water nanofluid flow in laminar and turbulent flows inside tubes fitted with diamond-shaped turbulators is numerically modeled. The nanofluid flow is modeled by employing a two-phase mixture method and applying the constant heat flux boundary condition at tube walls. In the results, the effects of different parameters such as the geometry of turbulators, volume fraction...

متن کامل

Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometry.

We report a new method for the diagnosis of homocystinuria and other hypermethioninemias from dried blood spots on newborn screening cards, based on isotope-dilution tandem mass spectrometry. The mean concentration of methionine in 909 unaffected newborns was 19 micromol/L (CV 44%). The variability of results was reduced when the concentration of methionine was expressed relative to that of ano...

متن کامل

Diversity of Variable Number Tandem Repeat Loci in Shigella Species Isolated From Pediatric Patients

Multilocus variable number tandem repeat (VNTR) analysis (MLVA) is a new typing method with several advantages compared to other methods. Dissemination of Shigella is highly significant in developing countries. Whilst Shigella is becoming increasingly important as an etiologic agent of pediatric shigellosis in Iran, little is known about the genetic diversity of the local strains. Therefore, th...

متن کامل

Numerical Simulation of CdS/CIGS Tandem Multi-Junction Solar Cells with AMPS-1D

Numerical modeling of polycrystalline thin-film solar cell serves as an imperative procedure to test the suitability of proposed physical clarification and to anticipate the effect of physical changes on cell performance. All in all, this must be conducted with only partial knowledge of input parameters. In this paper, we evaluated the numerical simulation of CdS/CIGS tandem multi junction sola...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004