چکیده

BACKGROUND Articular cartilage is a viscoelastic material, but its exact behaviour under the full range of physiological loading frequencies is unknown. The objective of this study was to measure the viscoelastic properties of bovine articular cartilage at loading frequencies of up to 92 Hz. METHODS Intact tibial plateau cartilage, attached to subchondral bone, was investigated by dynamic mechanical analysis (DMA). A sinusoidally varying compressive force of between 16 N and 36 N, at frequencies from 1 Hz to 92 Hz, was applied to the cartilage surface by a flat indenter. The storage modulus, loss modulus and phase angle (between the applied force and the deformation induced) were determined. RESULTS The storage modulus, E', increased with increasing frequency, but at higher frequencies it tended towards a constant value. Its dependence on frequency, f, could be represented by, E' = Alog(e) (f) + B where A = 2.5 +/- 0.6 MPa and B = 50.1 +/- 12.5 MPa (mean +/- standard error). The values of the loss modulus (4.8 +/- 1.0 MPa mean +/- standard deviation) were much less than the values of storage modulus and showed no dependence on frequency. The phase angle was found to be non-zero for all frequencies tested (4.9 +/- 0.6 degrees ). CONCLUSION Articular cartilage is viscoelastic throughout the full range of frequencies investigated. The behaviour has implications for mechanical damage to articular cartilage and the onset of osteoarthritis. Storage modulus increases with frequency, until the plateau region is reached, and has a higher value than loss modulus. Furthermore, loss modulus does not increase with loading frequency. This means that more energy is stored by the tissue than is dissipated and that this effect is greater at higher frequencies. The main mechanism for this excess energy to be dissipated is by the formation of cracks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variation in viscoelastic properties of bovine articular cartilage below, up to and above healthy gait-relevant loading frequencies

The aim of this study was to determine the variation in viscoelastic properties of femoral head bovine articular cartilage, on-bone, over five orders of magnitude of loading frequency. These frequencies ranged from below, up to and above healthy gait-relevant frequencies, using<1, 1-5 and 10 Hz, respectively. Dynamic mechanical analysis was used to measure storage and loss stiffness. A maximum ...

متن کامل

Regional Variation of Mechanical Properties in Human Mandibular Subchondral Bone Tissue

Introduction: The temporomandibular joint (TMJ) is a synovial joint that has a fibrocartilaginous articular disc located between the articular cartilage of the articular eminence of the temporal bone and the mandibular condyle. As masticatory muscles maintain the integrity of the TMJ, the components of the TMJ are constantly compressed during occlusion. During mastication, muscle contractions a...

متن کامل

Viscoelastic properties of bovine knee joint articular cartilage: dependency on thickness and loading frequency

BACKGROUND The knee is an incongruent joint predisposed to developing osteoarthritis, with certain regions being more at risk of cartilage degeneration even in non-osteoarthrosed joints.At present it is unknown if knee regions prone to cartilage degeneration have similar storage and/or loss stiffness, and frequency-dependent trends, to other knee joint cartilage. The aim of this study was to de...

متن کامل

Viscoelastic properties of human and bovine articular cartilage: a comparison of frequency-dependent trends

BACKGROUND The purpose of this study was to compare the frequency-dependent viscoelastic properties of human and bovine cartilage. METHODS Full-depth cartilage specimens were extracted from bovine and human femoral heads. Using dynamic mechanical analysis, the viscoelastic properties of eight bovine and six human specimens were measured over the frequency range 1 Hz to 88 Hz. Significant diff...

متن کامل

Tetrapolar measurement of electrical conductivity and thickness of articular cartilage.

A tetrapolar method to measure electrical conductivity of cartilage and bone, and to estimate the thickness of articular cartilage attached to bone, was developed. We determined the electrical conductivity of humeral head bovine articular cartilage and subchondral bone from a 1- to 2-year-old steer to be 1.14+/-0.11 S/m (mean+/-sd, n =11) and 0.306+/-0.034 S/m, (mean+/-sd, n =3), respectively. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Musculoskeletal Disorders

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009