Stabilizing sensitivity in large single-photon image sensors with an integrated 3.3-to-25V all-digital charge pump

نویسندگان

  • Shingo Mandai
  • Edoardo Charbon
چکیده

Abstract This paper presents a digitally controlled charge pump (DCP) to supply high voltages, while ensuring temperature and load current independence of excess bias in cameras based on avalanche photodiodes. This is achieved through a single-photon avalanche diode (SPAD) based monitoring mechanism that continuously reconfigures the DCP using a feedback loop to compensate breakdown voltage variations by temperature and load current in real time. The sensitivity of the SPADs, or photon detection probability, is maintained to within 1.9% when the temperature shifts from 28 ◦C to 65 ◦C and the load current changes from 0 μA to 100μA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

All-Digital Biomedical Imaging

The appearance of miniaturized single-photon detectors has enabled massively parallel conversion of photons to digital signals that can be readily processed and/or transported with negligible losses. As a consequence, a new class of imaging sensors is emerging, known collectively as all-digital image sensors, for detection and processing of ultra-fast and complex photonic events, often present ...

متن کامل

Low Settling Time All Digital DLL For VHF Application

Settling time is one of the most important parameter in design of DLLs. In this paper we propose a new high speed with low settling time Delay Locked Loop (DLL) in which a digital signal processor (DSP) is used instead of using phase-frequency detector, charge pump and loop filter in conventional DLL. To have better settling time, PRP conjugate gradient algorithm is used to optimize delay of ea...

متن کامل

A Novel Digital Closed Loop MEMS Accelerometer Utilizing a Charge Pump

This paper presents a novel digital closed loop microelectromechanical system (MEMS) accelerometer with the architecture and experimental evaluation. The complicated timing diagram or complex power supply in published articles are circumvented by using a charge pump system of adjustable output voltage fabricated in a 2P4M 0.35 µm complementary metal-oxide semiconductor (CMOS) process, therefore...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013