Comparison of a modified thiazole orange technique with a fully automated analyser for reticulocyte counting.
نویسندگان
چکیده
Two independent methods for quantitating reticulocyte counts were compared. One used a modified thiazole orange technique and a flow cytometer (Becton Dickinson FACS); the other was a fully automated whole blood analyser (Sysmex R1000). Both methods gave comparable results with a coefficient of variation of less than 5%. Samples measured using the R1000 showed a negligible decrease in the reticulocyte count over five days at room temperature, although there was evidence of continuing intracellular maturation: with thiazole orange there was an apparent increase. A practical reference range of 20-70 x 10(9)/l was established from 89 normal subjects. The close correlation between the two independent estimates indicates the validity of the quantitation of the reticulocyte count and shows that automation allows significant changes within and below the normal range to be detected with a degree of reliability which was not previously possible.
منابع مشابه
Reticulocyte counting by flow cytometry. A comparison with manual methods.
The reticulocyte count (RC) is a key diagnostic test in the evaluation, classification, and response to therapy of anemia. The RC, as determined by manual methods, has a frustrating inherent imprecision owing to its binomial counting statistics (i.e., low counts/low precision) and inaccuracy because of inter- and intraobserver variability as to what indeed is a reticulocyte. Fluorescent activat...
متن کاملReticulocyte counting using flow cytometry.
A flow cytometric method for the quantitation of reticulocytes was refined for routine laboratory use. Blood (2 microliters) is added to 2 ml of 0.4 microM thiazole orange in phosphate buffered saline, incubated at room temperature for 90 minutes, and analysed on a Coulter EPICS Profile flow cytometer, with gating for red cells on the basis of forward and right angled light scatter. Blood (2 mi...
متن کاملMicrosoft Word - NEF366BF
Dr. P. Zachée, Department of Hematology, University Hospital Leuven, Herestraat 49, B-3000 Leuven (Belgium) Table 1. Results of PVC, reticulocyte count, reticulocyte index and mean fluorescence before and after 3 months of rH-EPO treatment After rH-EPO p values Before rH-EPO Dear Sir, The enumeration of reticulocytes is the simplest, and perhaps the best way to assess effective red blood produc...
متن کاملOptimized Method for Reticulocyte Counting: Simple, Accurate, and Comparable to Flow Cytometry
Background: Reticulocytes are immature red blood cells with RNA, spending the final stages of their maturation in the peripheral blood. The number of reticulocytes in the peripheral blood is the salient evidence of the effectiveness of bone marrow to produce red blood cells. Currently, reticulocyte count is done manually or automatically in clinical laboratories. Difficulties and limitations of...
متن کاملHeinz bodies interfere with automated reticulocyte counts.
Correspondence: Ignacio Español, M.D., Laboratoris Folguera, c/ Aribau 212-216, entl 3a, 08006 Barcelona, Spain. Phone: international +34-93-4143481 – Fax: international +34-932021341. was low: 20 mg/dL. A very high reticulocyte count was detected by two different automated counters (Figure 1), but only one reported a staining error. A crisis of hemolytic anemia or an error in the automated ret...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 44 2 شماره
صفحات -
تاریخ انتشار 1991