Transient Stability of IEEE-30 bus system using E-TAP Software
نویسنده
چکیده
The main objective of this paper is to perform transient stability analysis using the electrical power systems design and analysis software namely ETAP. The purpose of performing transient stability on the power system is to study the stability of a system under various disturbances. The stability of the power system is the ability of generators to remain in synchronisation even when subjected to disturbances. In this research work a standard IEEE 30-bus system, subjected to various disturbances is considered. The swing curves for the various generators of IEEE 30-bus system is plotted to comment on the stability of the system. The factors affecting the stability are analysed and methods f o r obtaining a b e t t e r s t a b i l i t y o f t h e system under the fault conditions are also studied. Index Terms Transient Stability, Rotor angle, Power Angle, ETAP —————————— ——————————
منابع مشابه
Solution of Multi-Objective optimal reactive power dispatch using pareto optimality particle swarm optimization method
For multi-objective optimal reactive power dispatch (MORPD), a new approach is proposed where simultaneous minimization of the active power transmission loss, the bus voltage deviation and the voltage stability index of a power system are achieved. Optimal settings of continuous and discrete control variables (e.g. generator voltages, tap positions of tap changing transformers and the number of...
متن کاملEffective transient stability assessment based on composite indices
This paper presents a new composite index to analyze power system transient stability. Contingency ranking in power system transient stability is a complicated and time consuming task. To prevail over this difficulty, various indices are used. These indices are based on the concept of coherency, transient energy conversion between kinetic and potential energy and three dot products of the s...
متن کاملAssessment of ATC Using Voltage and Transient Stability, Simultaneously
Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...
متن کاملTransient Stability Analysis and Enhancement of Ieee- 9 Bus System
System stability study is the important parameter of economic, reliable and secure power system planning and operation. Power system studies are important during the planning and conceptual design stages of the project as well as during the operating life of the plant periodically. This paper presents the power system stability analysis for IEEE9 bus test system. The fault is created on differe...
متن کاملAssessment of ATC Using Voltage and Transient Stability, Simultaneously
Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...
متن کامل