Effect of biphasic shock duration on defibrillation threshold with different electrode configurations and phase 2 capacitances: prediction by upper-limit-of-vulnerability determination.

نویسندگان

  • P N Schauerte
  • K Ziegert
  • M Waldmann
  • F A Schöndube
  • F Birkenhauer
  • K Mischke
  • M Grossmann
  • P Hanrath
  • C Stellbrink
چکیده

BACKGROUND The defibrillation threshold (DFT) may be affected by biphasic shock duration (BSD), electrode configuration, and capacitance. The upper limit of vulnerability (ULV) may be used to estimate the DFT. For different lead configurations and phase 2 capacitances, we investigated in 18 pigs whether the use of ULV may predict waveforms with lowest DFT. METHODS AND RESULTS -DFT and ULV were determined by up-down protocols for 10 BSDs. ULVs were measured by T-wave scanning during ventricular pacing (cycle length 500 ms). In protocol 1 (n=6), a pectoral "active can" was combined with an electrode in the superior vena cava as common cathode and a right ventricle electrode as anode (AC+SVC). In protocol 2 and protocol 3 (n=6 each), only the "active can" was used as proximal electrode (AC). Capacitance was 150 microF during both phases in protocol 1 and protocol 3 but 150 microF (phase 1) and 300 microF (phase 2) in protocol 2. ULV and DFT demonstrated a linear correlation in each protocol (r=0.78 to 0.84). Lowest DFTs were found at 10 ms for AC+SVC and at 14 ms for AC (P<0.001). At optimal BSDs, voltage DFTs did not differ significantly between AC (527+/-57 V) and AC+SVC (520+/-70 V). Switching capacitors for phase 2 in a way that reduced leading-edge voltage by 50% while doubling capacity did not change BSD for optimal voltage DFT but increased minimum DFT from 527+/-57 V to 653+/-133 V (P=0.04). CONCLUSIONS The BSD with lowest DFT is shorter for AC+SVC than for AC. There is no significant difference in voltage DFT between both at optimal BSD. A lower phase 2 capacitance reduces DFTs irrespective of BSD. Because strength-duration curves for DFT and ULV correlate for different BSDs, lead systems, and phase 2 capacitances, ULV determination may allow the prediction of waveforms with lowest DFT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Relation of atrial refractoriness to upper and lower limits of vulnerability for atrial fibrillation/flutter following implantable ventricular defibrillator shocks.

BACKGROUND Implantable ventricular cardioverter defibrillator (ICD) shocks can cause atrial fibrillation/flutter (AF). This study investigated the pathogenesis of AF after ICD shocks in a canine model. METHODS AND RESULTS The study was conducted in 8 dogs. In 5 dogs (group 1), truncated exponential (8 ms, 78% tilt) monophasic and biphasic shocks were delivered through a bipolar epicardial (pa...

متن کامل

Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.

Electrode polarity has been reported to be one of the factors that affect defibrillation efficacy. We studied the influence of polarity on defibrillation efficacy when monophasic and biphasic waveforms were used with an endocardial lead system. In six anesthetized pigs, defibrillation catheters were placed in the right ventricular (RV) apex and at the junction of the superior vena cava (SVC) an...

متن کامل

Advantage of four-electrode over two-electrode defibrillators.

Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical ...

متن کامل

Upper limit of vulnerability reliably predicts the defibrillation threshold in humans.

BACKGROUND The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 99 11  شماره 

صفحات  -

تاریخ انتشار 1999