Robust EPI Nyquist ghost elimination via spatial and temporal encoding.
نویسندگان
چکیده
Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo planar imaging acquisition trajectory from frame to frame, enabling one to interleave data to remove inconsistencies that occur between sampling on positive and negative gradient readouts. With PLACE, one can coherently combine the interleaved data to cancel residual Nyquist ghosts. If the level of ghosting varies significantly from image to image, however, the signal cancellation that occurs with PLACE can adversely affect SNR-sensitive applications such as perfusion imaging with arterial spin labeling. This work proposes integrating PLACE into a PAGE-based reconstruction process to yield significantly better Nyquist ghost correction that is more robust than PLACE or PAGE alone. The robustness of this method is demonstrated in the presence of magnetic field drift with an in-vivo arterial spin labeling perfusion experiment.
منابع مشابه
Robust Elimination of EPI Nyquist Ghosts via Spatial and Temporal Encoding
Introduction: Nyquist ghosts are an inherent artifact in echo planar imaging (EPI). Many methods have been proposed to correct for them, with various strengths and weaknesses. Here, we propose a fusion of previous spatial [1] and temporal [2] encoding methods to achieve the goal of self-referenced ghost elimination with very low temporal latency. Methods: Our approach follows from the method de...
متن کاملRemoval of EPI Nyquist ghost artifacts with two-dimensional phase correction.
Odd-even echo inconsistencies result in Nyquist ghost artifacts in the reconstructed EPI images. The ghost artifacts reduce the image signal-to-noise ratio and make it difficult to correctly interpret the EPI data. In this article a new 2D phase mapping protocol and a postprocessing algorithm are presented for an effective Nyquist ghost artifacts removal. After an appropriate k-space data regro...
متن کاملDual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.
PURPOSE A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice-group. These navigator data may contain spatially nonlin...
متن کاملA Method to Remove Nyquist Ghosts from Echo Planar Images (EPI) using UNFOLD
Introduction: Nyquist ghosts are a persistent artifact in echo planar imaging (EPI), and occur when data sampled along positive readout gradients and negative read-out gradients is inconsistent. There are many approaches to correct such artifacts including double-sampled (DS) EPI [1], 1D phase-correction with an algorithm developed by Ahn and Cho (AC) [2], 2D phase-mapping [3], and phase labeli...
متن کاملImproved Self-Referenced Parallel MRI imaging in EPI by using UNFOLD to Remove Nyquist Ghosts
Introduction: The quality of parallel MRI (pMRI) reconstructions is directly dependent on the data used for coil sensitivity estimation in SENSE [1] and/or GRAPPA [2] reconstruction coefficient calibration. In many applications, it is desirable to use self-referenced pMRI approaches over a prescan approach, to limit the effect of changes (such as motion) that occur between acquisition of the pr...