Application of the solid phase C1q and Raji cell radioimmune assays for the detection of circulating immune complexes in glomerulonephritis.
نویسندگان
چکیده
The C1q solid phase and Raji cell radioimmune assays were used to determine the frequency of detectable circulating immune complexes in patients with glomerulonephritis. In this study, 46% of 56 patients with glomerulonephritis had evidence of circulating immune complexes. More important, circulating immune complexes were associated with some, but not other, types of glomerulonephritis. Thus, immune complexes were detected in lupus glomerulonephritis (9/9 patients), rapidly progressive glomerulonephritis (5/6 patients), and acute nephritis (5/6 patients), but not in IgA-IgG glomerulonephritis (0/7 patients), or membranous glomerulonephritis (0/8 patients). The Raji cell radioimmune assay and the C1q solid phase radioimmune assay showed concordance of 79% in the detection of circulating immune complexes. Serial determinations, in general, showed either persistence of a negative or positive result of conversion of positive to negative.
منابع مشابه
Circulating immune complexes in Lyme arthritis. Detection by the 125I-C1q binding, C1q solid phase, and Raji cell assays.
We have found immunoglobulin (Ig) G-containing material consistent with immune complexes in the sera of patients with Lyme arthritis. It was detected in 29 of 55 sera (55%) from 31 patients by at least one of three assays: (125)I-C1q binding, C1q solid phase, or Raji cell. The presence of reactive material correlated with clinical aspects of disease activity; it was found early in the illness, ...
متن کاملSolid-phase Clq-binding fluorescence immunoassay for detection of circulating immune complexes.
A fluorescence immunoassay for detection of immune complexes bound to solid-phase C1q was developed. The method was standardized by using human aggregated immunoglobulin G (IgG) to simulate immune complexes. A linear relationship existed between the concentrations of the aggregated IgG standards and the resulting fluorescent intensity. The method was found to be reproducible and capable of dete...
متن کاملThe Nature of Immune Complexes in Human Cancer Sera 1
Sera from 517 patients with various types of malignancies were assayed for immune complexes (ICs) by the Raji cell radioimmune assay. The incidence of immune complexes in these patients ranged from 16 to 52% as compared to 19% in normal controls. Increases in tumor mass and metastatic disease were associated with high levels of circulating ICs. Immunization of melanoma patients with BCG and tum...
متن کاملIn vitro methods for detection of circulating immune complexes.
The possible pathologic consequences of the presence of circulating immune complexes in certain disease states has caused considerable attention to be given to the development of laboratory procedures capable of quantitatively measuring the presence of immune complexes in serum. Many assays are available which utilize differing properties of immune complexes for their detection. Examples of ass...
متن کاملAssociation of levels of circulating C1q binding macromolecules with induction chemotherapy response in head and neck cancer patients.
Ninety-five untreated patients with squamous cell carcinoma of the upper aerodigestive tract expressed significantly higher levels of C1q-binding macromolecules as compared to 45 noncancer-bearing controls. No relationship between C1q-binding macromolecules and levels of circulating IgG-immune complexes as determined by the solid-phase C1q-binding assay or the C3d-solid-phase assay could be def...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of clinical investigation
دوره 62 1 شماره
صفحات -
تاریخ انتشار 1978