Magnetic resonance imaging with respiratory gating: techniques and advantages.
نویسندگان
چکیده
Respiratory motion is an important problem in magnetic resonance imaging (MRI) of the thorax and upper abdomen. This study assessed several approaches for practical respiratory gating. Methods of acquiring respiratory signals, gated sequencing methods, duration of examination, strategies for reducing examination time, diagnostic quality of gated images, and the influence of respiratory gating on relaxation time measurements were evaluated. Of three different devices for acquiring the respiratory signal, a belt containing a displacement transducer placed around the upper abdomen was found to be most effective and practical. Two pulse-gating modes were implemented, as well as a method for combining cardiac and respiratory gating. Gating methods were tested using phantoms and human volunteers. A spin-conditioned mode of respiratory gating was found to be superior to a more simply implemented triggered mode in which spin-echo (SE) sequencing was interrupted. The time penalty for respiratory gating is technique-dependent. Gated studies with uncontrolled tidal breathing took two to four times longer than nongated studies. When the time between respirations was voluntarily prolonged, gated studies could be only 30%-50% longer than nongated. The standard deviation of relaxation-time measurements for organs that are displaced during respirations was substantially reduced by respiratory gating. Gating acquisition without spin-conditioning gating. Respiratory gating is a practical and useful technique for improving the contrast and spatial resolution of SE images of the upper abdomen and chest. SE images produced with short repetition times were particularly improved by respiratory gating.
منابع مشابه
Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملBimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملResting-state Functional Connectivity During Controlled Respiratory Cycles Using Functional Magnetic Resonance Imaging
Introduction: This study aimed to assess the effect of controlled mouth breathing during the resting state using functional magnetic resonance imaging (fMRI). Methods: Eleven subjects participated in this experiment in which the controlled “Nose” and “Mouth” breathings of 6 s respiratory cycle were performed with a visual cue at 3T MRI. Voxel-wise seed-to-voxel maps and whole-brain region of i...
متن کاملComparison of respiratory motion suppression techniques for 4D flow MRI.
PURPOSE The purpose of this work was to assess the impact of respiratory motion and to compare methods for suppression of respiratory motion artifacts in 4D Flow MRI. METHODS A numerical 3D aorta phantom was designed based on an aorta velocity field obtained by computational fluid mechanics. Motion-distorted 4D Flow MRI measurements were simulated and several different motion-suppression tech...
متن کاملPreliminary investigation of respiratory self-gating for free-breathing segmented cine MRI.
Segmented cine MRI generally requires breath-holding, which can be problematic for many patients. Navigator echo techniques, particularly successful for free-breathing coronary MRA, are incompatible with the acquisition strategies and SSFP pulse sequences commonly used for cine MRI. The purpose of this work is to introduce a new self-gating technique deriving respiratory gating information dire...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 143 6 شماره
صفحات -
تاریخ انتشار 1984