Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography.
نویسندگان
چکیده
OBJECTIVE To develop a technique for volumetric analysis of real time three dimensional echocardiography (RT3DE) data aimed at quantifying left ventricular (LV) mass and to validate the technique against magnetic resonance (MR) assumed as the reference standard. DESIGN RT3DE, which has recently become widely available, provides dynamic pyramidal data structures that encompass the entire heart and allows four dimensional assessment of cardiac anatomy and function. However, analysis techniques for the quantification of LV mass from RT3DE data are fundamentally two dimensional, rely on geometric modelling, and do not fully exploit the volumetric information contained in RT3DE datasets. Twenty one patients underwent two dimensional echocardiography (2DE), RT3DE, and cardiac MR. LV mass was measured from 2DE and MR images by conventional techniques. RT3DE data were analysed to semiautomatically detect endocardial and epicardial LV surfaces by the level set approach. From the detected surfaces, LV mass was computed directly in the three dimensional space as voxel counts. RESULTS RT3DE measurement was feasible in 19 of 21 patients and resulted in higher correlation with MR (r = 0.96) than did 2DE (r = 0.79). RT3DE measurements also had a significantly smaller bias (-2.1 g) and tighter limits of agreement (2SD = +/-23 g) with MR than did the 2DE values (bias (2SD) -34.9 (50) g). Additionally, interobserver variability of RT3DE (12.5%) was significantly lower than that of 2DE (24.1%). CONCLUSIONS Direct three dimensional model independent LV mass measurement from RT3DE images is feasible in the clinical setting and provides fast and accurate assessment of LV mass, superior to the two dimensional analysis techniques.
منابع مشابه
Improved quantification of left ventricular mass based on endo- and epicardial surface detection using real-time three-dimensional echocardiography
Objective: Our goal was to develop a technique for volumetric analysis of real-time three-dimensional echocardiography (RT3DE) data aimed at quantification of LV mass and validate it against magnetic resonance (MR) assumed as “gold standard”. Design: RT3DE, which has recently become widely available, provides dynamic pyramidal data structures that encompass the entire heart and allows four-dime...
متن کاملReal-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function—Current Clinical Applications and Literature Review Update
Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles includ...
متن کاملComparison of cardiovascular magnetic resonance with real-time three-dimensional echocardiography and the right ventricular automated systolic index in the assessment of the right ventricular function
Background The right ventricular (RV) function has an important diagnostic value in many cardiopulmonary diseases and is a predictor for the long-term outcome. Cardiovascular magnetic resonance (CMR) is the gold-standard for the RV quantification as the complex anatomy of the RV, i.e. its crescentic shape, impedes reliable measurement by two-dimensional echocardiography (EC). Yet, CMR or real-t...
متن کاملThree-dimensional electrophysiological imaging of the intact canine left ventricle using a noncontact multielectrode cavitary probe: study of sinus, paced, and spontaneous premature beats.
BACKGROUND The feasibility of measuring cavitary electrograms using a noncontact probe and reconstructing endocardial surface electrograms and activation sequences during paced beats was previously demonstrated in the isolated canine left ventricle (LV). The objective of the present study was to develop and test a high-resolution, three-dimensional, endocardial electrophysiological imaging tech...
متن کاملFunction and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking.
One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 92 2 شماره
صفحات -