An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients.
نویسندگان
چکیده
BACKGROUND Although core temperature can be measured invasively, there are currently no widely available, reliable, noninvasive thermometers for its measurement. We thus compared a prototype zero-heat-flux thermometer with simultaneous measurements from a pulmonary artery catheter. Specifically, we tested the hypothesis that zero-heat-flux temperatures are sufficiently accurate for routine clinical use. METHODS Core temperature was measured from the thermistor of a standard pulmonary artery catheter and with a prototype zero-heat-flux deep-tissue thermometer in 105 patients having nonemergent cardiac surgery. Zero-heat-flux probes were positioned on the lateral forehead and lateral neck. Skin surface temperature probes were attached to the forehead just adjacent to the zero-heat-flux probe. Temperatures were recorded at 1-minute intervals, excluding the period of cardiopulmonary bypass, and for the first 4 postoperative hours. Zero-heat-flux and pulmonary artery temperatures were compared with bias analysis; differences exceeding 0.5°C were considered to be potentially clinically important. RESULTS The mean duration in the operating room was 279 ± 75 minutes, and the mean cross-clamp time was 118 ± 50 minutes. All subjects were monitored for an additional 4 hours in the intensive care unit. The average overall difference between forehead zero-heat-flux and pulmonary artery temperatures (i.e., forehead minus pulmonary artery) was -0.23°C (95% limits of agreement of ±0.82); 78% of the differences were ≤0.5°C. The average intraoperative temperature difference was -0.08°C (95% limits of agreement of ±0.88); 84% of the differences were ≤0.5°C. The average postoperative difference was -0.32°C (95% limits of agreement of ±0.75); 84% of the differences were ≤0.5°C. Bias and precision values for neck site were similar to the forehead values. Uncorrected forehead skin temperature showed an increasing negative bias as core temperature decreased. CONCLUSIONS Core temperature can be noninvasively measured using the zero-heat-flux method. Bias was small, but precision was slightly worse than our designated 0.5°C limits compared with measurements from a pulmonary artery catheter.
منابع مشابه
Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery.
OBJECTIVE The aim of this study was to compare deep body temperature obtained using a novel noninvasive continuous zero-heat-flux temperature measurement system with core temperatures obtained using conventional methods. DESIGN A prospective, observational study. SETTING Operating room of a university hospital. PARTICIPANTS The study comprised 15 patients undergoing vascular surgery of th...
متن کاملEvaluation of extracorporeal blood heat exchanger devices.
An accurate and easy to use test circuit has been developed for the performance evaluation of the heat exchangers used in cardiac surgery during extracorporeal circulation. The water part of the heat exchanger is fixed at a flow rate of 15 l/min and at a temperature of 40 degrees C. In the blood side, the flow rate is varied from 1 to 6 l/min and the temperature is 30 degrees C. The use of a pr...
متن کاملSurgical management of cardiac tamponade: Is left anterior minithoracotomy really safe and effective?
Objective: Cardiac tamponade is a life-threatening clinical entity that requires an emergency treatment. Cardiac tamponade can be caused both by benign and malignant diseases. A variety of methods have been described for the treatment of these cases from needle-guided pericardiocentesis, balloon-based techniques to surgical pericardiotomy. The Authors report their experience in...
متن کاملPropranolol for infantile hemangioma: An evaluation of its efficacy and safety in Iranian infants
Background: Propranolol has been recently indicated to inhibit the rapid growth and involution of infantile hemangioma. In the present study, we investigated the efficacy and safety of propranolol in Iranian infants. Methods: A total of 30 infants with indications for medical intervention, such as large hemangiomas, wounds with or without secondary infection, or active trauma-induced bleeding,...
متن کاملConvective Heat Transfer of Oil Based Nanofluid Flow Inside a Circular Tube
Abstract An empirical investigation was carried out to study convective heat transfer of nanofluid flow inside an inclined copper tube under uniform heat flux condition. Required data are acquired for laminar and hydrodynamically fully developed flow inside round tube. The stable CuO-base oil nanofluid with different nanoparticle weight fractions of 0.5%, 1% and 2% was produced by means of ul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 119 3 شماره
صفحات -
تاریخ انتشار 2014