How does angioplasty work? Serial analysis of human iliac arteries using intravascular ultrasound.

نویسندگان

  • D W Losordo
  • K Rosenfield
  • A Pieczek
  • K Baker
  • M Harding
  • J M Isner
چکیده

BACKGROUND Previous studies regarding the mechanism by which balloon angioplasty increases luminal patency have generally used animal models or postmortem specimens from occasional fatal cases of angioplasty performed in human patients. In either case, conclusions regarding participatory mechanisms have relied exclusively on nonserial, postangioplasty histopathological examination. METHODS AND RESULTS In the present study, intravascular ultrasound examination was performed before and after balloon angioplasty in 40 consecutive patients with iliac artery stenoses. The areas of the arterial wall, plaque, lumen, and areas resulting from angioplasty-induced plaque fractures were measured immediately after angioplasty in vivo and compared with findings recorded immediately before angioplasty. Angioplasty increased luminal cross-sectional area (CSA) from 11.5 +/- 0.6 mm2 before angioplasty to 25.4 +/- 1.2 mm2 after angioplasty (p = 0.0001). CSA of the portion of the postangioplasty neolumen contained within angioplasty-induced plaque fractures measured 10.0 +/- 0.8 mm2; the neolumen excluding the area contributed by these plaque fractures measured 15.4 +/- 0.8 mm2. Thus, the area contained within plaque fractures accounted for 10.0 mm2 (71.9%) of the 13.9-mm2 increase in luminal CSA after angioplasty. Analysis of CSA occupied by atherosclerotic plaque disclosed that plaque CSA decreased from 33.8 +/- 1.8 mm2 before angioplasty to 22.5 +/- 1.5 mm2 after angioplasty (p = 0.0001). Plaque CSA was thus reduced ("compressed") by 11.3 +/- 1.1 mm2. Total artery CSA increased ("stretched") slightly from 45.3 +/- 2.6 mm2 before angioplasty to 47.8 +/- 2.0 mm2 after angioplasty (p = 0.0025). CONCLUSIONS In vivo analysis of iliac stenoses by intravascular ultrasound immediately before and after angioplasty demonstrates that plaque fractures and "compression" of atherosclerotic plaque are the principal factors responsible for increased luminal patency resulting from balloon angioplasty. "Stretching" of the arterial wall provides an additional, but minor, contribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial Analysis of Human Iliac Arteries Using Intravascular Ultrasound

Background. Previous studies regarding the mechanism by which balloon angioplasty increases luminal patency have generally used animal models or postmortem specimens from occasional fatal cases of angioplasty performed in human patients. In either case, conclusions regarding participatory mechanisms have relied exclusively on nonserial, postangioplasty histopathological examination. Methods and...

متن کامل

Effects of intravascular cryotherapy on vessel wall repair in a balloon-injured rabbit iliac artery model.

OBJECTIVE Although the application of cold energy, cryotherapy, has been shown to cause selective damage to cellular components with preservation of matrix structure resulting in less fibrosis in a variety of tissues, the effects of intravascular cryotherapy on vessel wall repair after balloon angioplasty are unknown. We sought to characterize the effects of cryotherapy application on vessel wa...

متن کامل

Effect of cilostazol on neointimal hyperplasia in iliac arteries of pigs after transluminal angioplasty Efeito do cilostazol na hiperplasia neointimal em artérias ilíacas de suínos submetidas à angioplastia transluminal

Objective: to evaluate whether systemic administration of cilostazol reduces neointimal hyperplasia in iliac arteries of pigs submitted to balloon catheter angioplasty. Methods: twenty pigs underwent angioplasty with a 6x40 mm balloon catheter in the right common iliac artery, guided by Doppler ultrasound. The animals were randomized into two groups: group 1 (n=10), which received 50mg cilostaz...

متن کامل

Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.

BACKGROUND Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND RESULTS A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from ather...

متن کامل

Vascular stenting in normal and atherosclerotic rabbits. Studies of the intravascular endoprosthesis of titanium-nickel-alloy.

Percutaneous transluminal balloon angioplasty would be more effective if the rate of recurrent stenosis were reduced. To evaluate the prevention of restenosis after percutaneous transluminal angioplasty, intravascular endoprosthetic stents of titanium-nickel-alloy were implanted transluminally in seven normal and 21 atherosclerotic rabbits. In normal rabbits, a 3.5-mm diameter stent was implant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 86 6  شماره 

صفحات  -

تاریخ انتشار 1992