Comparison of the Inverted Internal Limiting Membrane Flap Technique and the Internal Limiting Membrane Peeling for Macular Hole with Retinal Detachment
نویسندگان
چکیده
PURPOSE To evaluate the efficacy of the inverted internal limiting membrane (ILM) flap technique in vitrectomy for macular hole (MH) with retinal detachment (RD) compared with vitrectomy using ILM peeling. METHODS A retrospective case series study was performed. Twenty-two eyes of 22 patients who underwent vitrectomy for MH with RD and followed-up more than 12 months after the surgery were included in this study. We retrospectively reviewed the medical records of patients who underwent vitrectomy with inverted ILM flap technique or vitrectomy with ILM peeling. Ten patients who had been treated vitrectomy with inverted ILM flap technique, and 12 patients who had been treated vitrectomy with ILM peeling were analyzed. We evaluated changes in best-corrected visual acuity (BCVA) before and after surgery, closing rates of MH, and retinal reattachment rates and compared between both groups. RESULTS MH was closed and RD was reattached postoperatively in 9 eyes (90%) in the inverted ILM flap group. In the ILM peeling group, the MH was closed in 4 eyes (33.3%) and the retinas were reattached in 6 eyes (50%) after surgery. Significant improvement in BCVA after surgery (P = 0.0017) was only found in the inverted ILM flap group. CONCLUSIONS Higher rates of closed MH and retinal reattachment, and small but significant improvement in BCVA were found in the inverted ILM flap group. Based on our data, the inverted ILM flap technique may be useful in vitrectomy for MH with RD.
منابع مشابه
Vitrectomy with internal limiting membrane peeling versus inverted internal limiting membrane flap technique for macular hole-induced retinal detachment: a systematic review of literature and meta-analysis
BACKGROUND To evaluate the effects on vitrectomy with internal limiting membrane (ILM) peeling versus vitrectomy with inverted internal limiting membrane flap technique for macular hole-induced retinal detachment (MHRD). METHODS Pubmed, Cochrane Library, and Embase were systematically searched for studies that compared ILM peeling with inverted ILM flap technique for macular hole-induced reti...
متن کاملDouble Internal Limiting Membrane Insertion for Macular Hole-Associated Retinal Detachment
PURPOSE To describe a modified technique of internal limiting membrane (ILM) insertion for macular hole- (MH-) associated retinal detachment (RD) in highly myopic eyes. METHODS Nine eyes underwent pars plana vitrectomy, cortical vitreous removal, and fovea-sparing ILM peeling. Double ILM insertion into the hole was performed with inverted perifoveal ILM and a free ILM flap followed by air-flu...
متن کاملSuccessful Closure of Iatrogenic Double Macular Hole Using inverted Internal Limiting Membrane Flap Technique-Case Report
Purpose: To present a case study describing inverted internal limiting membrane flap technique used after failed treatment of double large fullthickness macular hole. Case presentation: A 79-year-old woman presented large full-thickness macular hole after primary failed pars plana vitrectomy with internal limiting membrane (ILM) peeling and SF6 gas endotamponade. The corrected distance visual a...
متن کاملManagement of rhegmatogenous retinal detachment with coexisting macular hole: a comparison of vitrectomy with and without internal limiting membrane peeling.
PURPOSE To compare the outcomes of vitrectomy with or without internal limiting membrane peeling for rhegmatogenous retinal detachment and coexisting macular hole. METHODS Thirty-one consecutive patients (31 eyes) with macula-off retinal detachment, peripheral breaks and a coexisting macular hole were prospectively enrolled over a 3-year period. All patients underwent vitrectomy with encircla...
متن کاملFoveal microstructure in macular holes surgically closed by inverted internal limiting membrane flap technique.
PURPOSE To evaluate reconstructive foveal anatomical change in surgically closed macular hole (MH) by pars plana vitrectomy with inverted internal limiting membrane flap technique. METHODS Spectral domain optical coherence tomography was used to evaluate foveal microstructures in 20 eyes of 19 patients who underwent pars plana vitrectomy with inverted internal limiting membrane flap technique...
متن کامل