Nitrous Oxide Sedation and Bispectral Index
نویسندگان
چکیده
OBJECTIVES To determine whether bispectral analysis (BIS) changes during nitrous oxide (N(2)O) sedation in anxious children undergoing extraction of primary teeth. METHODS In this prospective study 45, ASA physical status I children, aged between 7 to 12 years and scheduled for primary teeth extraction under N(2)O/O(2) sedation are included. At baseline (T0) and during the sedation procedure (T1-6); BIS levels, Ramsay Sedation Scores (RSS), oxygen saturation (Sp0(2)), and heart rate (HR) were recorded at one-minute intervals. Forty percent N(2)O in O(2) was given by a nasal hood, and N(2)O concentration was enhanced to 60% in a two-minute period. Paired measurements of BIS levels with Observer's Assessment of Alertness and Sedation (OAA/S) scores were obtained during sedation procedure. RESULTS Since 5 patients refused application of the nasal hood, a total 40 of the original 45 subjects completed the study. Mean age and weight of the children were 9.5 +/- 1.4 years and 23.7 +/- 9.7 kg, respectively. Nitrous oxide inhalation produced no changes in BIS levels despite a sedation level in OAA/S scores were observed at 40-60% N(2)O concentrations. CONCLUSIONS BIS values do not change during N(2)O/O(2) sedation and the BIS monitor is not appropriate to evaluate the depth of sedation provided by N(2)O/O(2) during primary teeth extraction in children.
منابع مشابه
V. 'For now we see through a glass, darkly': the anaesthesia syndrome.
J Neurosci Methods 2007; 160: 215–22 17 Shafer SL, Hendrickx JF, Flood P, Sonner J, Eger EI II. Additivity versus synergy: a theoretical analysis of implications for anesthetic mechanisms. Anesth Analg 2008; 107: 507–24 18 Kuhlmann L, Foster BL, Liley DT. Modulation of functional EEG networks by the NMDA antagonist nitrous oxide. PLoS One 2013; 8: e56434 19 Barr G, Jakobsson JG, Owall A, Anders...
متن کاملParadoxical changes in bispectral index during nitrous oxide administration.
I report two patients undergoing open heart surgery, with nitrous oxide and isoflurane anaesthesia, for whom bispectral index (BIS) monitoring showed high BIS values with nitrous oxide and isoflurane anaesthesia. The BIS decreased immediately after nitrous oxide was stopped and increased again after nitrous oxide was restarted.
متن کاملAutomated responsiveness test and bispectral index monitoring during propofol and propofol/N2O sedation.
BACKGROUND Sedation practice, especially when non-anaesthesia personnel are involved, requires efficient anaesthetic depth monitoring. Therefore, we used prediction probability (PK) to evaluate the performance of the bispectral index (BIS) of the EEG and automated responsiveness test (ART) to predict sedation depth and loss of subject's responsiveness during propofol sedation, with and without ...
متن کاملPropofol Requirement during Propofol and Butorphanol Anesthesia with and without Nitrous Oxide in Short Duration Intracranial Surgeries: A Bispectral Index Guided Study
Neurosurgical anesthesia; Nitrous oxide; Bispectral index
متن کاملNitrous oxide does not alter bispectral index: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia.
We have studied the effect of nitrous oxide on bispectral index (BIS), calculated from a bipolar encephalogram. Inhalation of 70% nitrous oxide resulted in loss of consciousness in all healthy volunteers (n = 10) but no change in BIS. Brief inhalation up to 1.2% sevoflurane also resulted in loss of consciousness in volunteers (n = 5), but with sevoflurane, BIS decreased. BIS and the haemodynami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of dentistry
دوره 1 شماره
صفحات -
تاریخ انتشار 2007