Myocardium at risk can be determined by ex vivo T2-weighted magnetic resonance imaging even in the presence of gadolinium: comparison to myocardial perfusion single photon emission computed tomography.

نویسندگان

  • Joey F A Ubachs
  • Henrik Engblom
  • Sasha Koul
  • Mikael Kanski
  • Patrik Andersson
  • Jesper van der Pals
  • Marcus Carlsson
  • David Erlinge
  • Håkan Arheden
چکیده

AIMS Determination of the myocardium at risk (MaR) and final infarct size by cardiac magnetic resonance imaging (CMR) enables calculation of salvaged myocardium in acute infarction. T2-weighted imaging is performed prior to the administration of gadolinium, since gadolinium affects T2 tissue properties. This is, however, difficult in an ex vivo model since gadolinium must be administered for determination of infarct size by CMR. We aimed to test the ability of ex vivo T2-weighted imaging to assess MaR using myocardial perfusion single photon emission computed tomography (SPECT) as reference and to investigate whether MaR could be assessed by ex vivo T2-weighted imaging after injection of gadolinium. Materials and methods In 18 domestic pigs, the left anterior descending artery was occluded for either 30 or 40 min, followed by 4 h of reperfusion. After explantation of the hearts, myocardial perfusion SPECT and T2-weighted imaging were performed for determination of MaR, either with or without gadolinium. Infarct size was determined by T1-weighted imaging and by triphenyl tetrazolium chloride (TTC) staining. RESULTS T2-weighted imaging agreed with myocardial perfusion SPECT, both with and without gadolinium (r(2)= 0.70, P < 0.01) with a bias of 2.6 ± 5.1% (P = 0.04). Infarct size was 15.4 ± 5.3 and 22.1 ± 5.6% with TTC and T1-weighted imaging, respectively (P = 0.008) in nine pigs who had both infarct measures. CONCLUSION T2-weighted CMR imaging can be used to determine MaR in an ex vivo experimental model, both with and without the presence of gadolinium. Thus, CMR alone can be used to assess myocardial salvage in experimental studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiovascular magnetic resonance of the myocardium at risk in acute reperfused myocardial infarction: comparison of T2-weighted imaging versus the circumferential endocardial extent of late gadolinium enhancement with transmural projection

BACKGROUND In the situation of acute coronary occlusion, the myocardium supplied by the occluded vessel is subject to ischemia and is referred to as the myocardium at risk (MaR). Single photon emission computed tomography has previously been used for quantitative assessment of the MaR. It is, however, associated with considerable logistic challenges for employment in clinical routine. Recently,...

متن کامل

Gadolinium-Enhancedmagnetic resonance imagingin hypertrophic cardiomyopathy

In vivo magnetic resonance imaging (MRI) of the heart with gadolinium-based contrast agents has been performed since the mid-1980s (1). A major limitation of the initial techniques was insufficient image contrast between normal and infarcted myocardium. Recently, a number of studies have demonstrated the effectiveness of a new segmented inversion recovery MRI pulse sequence for differentiating ...

متن کامل

Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction

BACKGROUND Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up to 1 week after AMI. Our aim was to validate CE-SSFP for determination of MaR in an experimental ...

متن کامل

Extent of Myocardium at Risk for Left Anterior Descending Artery, Right Coronary Artery, and Left Circumflex Artery Occlusion Depicted by Contrast-Enhanced Steady State Free Precession and T2-Weighted Short Tau Inversion Recovery Magnetic Resonance Imaging.

BACKGROUND Contrast-enhanced steady state free precession (CE-SSFP) and T2-weighted short tau inversion recovery (T2-STIR) have been clinically validated to estimate myocardium at risk (MaR) by cardiovascular magnetic resonance while using myocardial perfusion single-photon emission computed tomography as reference standard. Myocardial perfusion single-photon emission computed tomography has be...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2013