Effects of Step Pool Porosity upon Flow Aeration and Energy Dissipation on Pooled Stepped Spillways
نویسندگان
چکیده
The hydraulics of stepped spillways with flat steps has been studied for the last three decades, including for embankment dam slopes, but studies of alternative stepped designs are limited. In this study, a pooled stepped spillway was investigated in a relatively large-size facility, and three different pool wall porosities were tested. The flow patterns, the macroand microscopic air-water flow properties, and the energy dissipation performances were recorded; the results were compared with the flat stepped spillway design for the same chute slope (θ 1⁄4 26.6°). The investigations highlighted a close agreement between air-water flow properties on the configurations in terms of void fraction, turbulence levels, bubble count rate, and chord sizes. The interfacial velocity distributions showed larger interfacial velocity on the pooled step configurations of approximately 5–10% linked with a reduced flow depth. On the porous pooled stepped spillways, the interfacial velocities within the cavity highlighted the flow through the pores and the reduction in cavity recirculation. The porous pooled weir reduced the form drag, and the residual energy was approximately 1.5–2 times larger on the porous pooled stepped chute with Po 1⁄4 31% and approximately 1.3 times larger on the porous steps with Po 1⁄4 5% compared with the flat stepped chute. The flat step design appeared to be the most advantageous in terms of flow stability and energy dissipation performance. DOI: 10.1061/(ASCE)HY.1943-7900.0000858. © 2014 American Society of Civil Engineers. Author keywords: Porous pooled steps; Pooled steps; Stepped spillway; Flow aeration; Energy dissipation; Flow resistance.
منابع مشابه
Flow aeration, cavity processes and energy dissipation on flat and pooled stepped spillways for embankments
The design floods of several reservoirs were recently re-evaluated and the revised spillway outflow could result in dam overtopping with catastrophic consequences for some embankment structures. Herein a physical study was performed on flat and pooled stepped spillways with a slope typical of embankments (θ = 26.6◦) and four stepped configurations were tested: a stepped spillway with flat horiz...
متن کاملAeration, Flow Instabilities, and Residual Energy on Pooled Stepped Spillways of Embankment Dams
Air-water flow experiments were conducted on some flat and pooled stepped spillways with slopes of 8.9° and 26.6° in transition and skimming flows. The study comprised the observations of the flow patterns, characteristic air-water flow properties, and energy dissipation performances. The air-water flow properties showed some differences in terms of interfacial velocity, bubble count rate, and ...
متن کاملStepped Spillway Performance: Study of the Pressure and Turbulent Kinetic Energy versus Discharge and Slope
In the present study, flow over flat and pooled stepped spillways was simulated three dimensionally. The VOF method and k- ε (RNG) turbulent model was used to simulate the flow over the stepped spillway. The results indicated that the numerical model was acceptably capable of simulating the flow over the pooled and flat stepped spillways for different discharges. Following that, the effect of d...
متن کاملAeration and air–water mass transfer on stepped chutes with embankment dam slopes
Stepped spillwayflows are characterised by significant free-surface aeration downstream of the inception point of air entrainment. The stepped design is advantageous for applications which require large energy dissipation and strong flow aeration. While the energy dissipation rate for embankment stepped spillways was studied previously, the optimum design for aeration and air–water mass transfe...
متن کاملFlat and Pooled Stepped Spillways for Overflow Weirs and Embankments: Cavity Flow Processes, Flow Aeration and Energy Dissipation
For overflow weirs and embankments, the stepped chute profile may increase the rate of energy dissipation on the waterway. Herein four different stepped chute configurations were tested with a focus on the cavity flow processes, flow aeration and energy dissipation performances. Detailed flow visualisations and air-water flow measurements were conducted for all configurations. The results highl...
متن کامل