Human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma are currently widely used clinically for prognostication and in monitoring antiretroviral therapy. Accurate and reproducible results are critical for patient management. To determine the effects of specimen collection and handling procedures on quantitative measurement of HIV-1 RNA, we compared anticoagulants and sample processing times. Whole blood was collected from 20 HIV-1-infected patients in EDTA, acid citrate dextrose (ACD), and heparin tubes, aliquoted, and stored at room temperature. Plasma was separated from whole-blood aliquots prepared at < or =1, 3, 6, 24, and 48 h postcollection and then stored at -70 degrees C until use. HIV-1 RNA levels were determined by the AMPLICOR HIV-1 MONITOR assay. Heparinized plasma samples, which were pretreated with heparinase prior to analysis, had the lowest baseline HIV-1 RNA levels. In the first 6 h, HIV-1 RNA levels decreased by 10, 20, and 31% in EDTA, ACD, and heparin tubes, respectively. From 6 to 48 h postcollection, HIV-1 RNA levels decreased in all anticoagulants, albeit at a slower, more consistent rate. Our results indicate that EDTA should be the anticoagulant of choice for plasma HIV-1 RNA measurement by reverse transcriptase PCR, but ACD tubes are acceptable if the plasma is separated within 6 h of blood collection. Caution must be applied in the interpretation of absolute HIV-1 RNA copy number values obtained with suboptimal specimen collection and processing procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Human Influenza Viruses in Nasopharyngeal Samples by RT-PCR vs Tissue Culture

Background and Aims: Influenza virus is a major pathogen involved in respiratory illnesses during winter seasons. A variety of diagnostic methods have been developed to identify influenza viruses in clinical specimen. Methods: Nasal and pharyngeal samples taken from patients were inoculated into Madin-Darby canine kidney (MOCK) cells and embryonated chicken eggs (ECEs). The culture media was a...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Ultrasensitive reverse transcription-PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma.

With the recent introduction of combination therapy, human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma have been dramatically reduced, frequently to below the limit of quantitation (400 copies/ml of plasma) of the AMPLICOR HIV-1 MONITOR Test (Roche Diagnostic Systems). To achieve enhanced sensitivity of the AMPLICOR HIV-1 MONITOR Test, a modified specimen preparation procedure th...

متن کامل

Rapid and accurate diagnosis of Foot-and-mouth disease virus by Real-time PCR in field samples

During 2010-2011, Real-time PCR procedure was used to detecting FMDV RNA on 147 epithelium samples from the field. In this survey, for Real-time PCR from 3D gene segment as conserve region selected for tracking all of seven serotypes FMDV. The assay detected the viral RNA in all serotypes of FMDV. The rRT-PCR specifically detected FMD virus in sample with greater sensitivity than our convention...

متن کامل

Cytomegalovirus Active Infection in Persons Infected with Human Immunodeficiency Virus

Background and Objective: Cytomegalovirus (CMV), one of the most common opportunistic pathogens in patients infected with human immunodeficiency virus (HIV), can cause the diseases such as encephalitis, pneumonia, and chorioretinitis. This study aimed at molecular studying of CMV infection in individuals infected with the human immunodeficiency virus. Material and Methods: In this study, 50 ven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 1998