Contact urticaria due to a face mask coated with disinfectant liquid spray.
نویسندگان
چکیده
Contact urticaria is defined as a wheal-and-flare reaction that occurs after epicutaneous contact with a causative agent (1). Contact urticaria usually appears within minutes after contact with the causative substances, including chemicals, animal products, antibiotics and cosmetics. We report here a case of contact urticaria resulting from exposure to a disinfectant liquid spray containing ethoxysilane-based quaternary ammonium salt (Chemical Abstracts Service (CAS): 62117-57-1). A 50-year-old housewife presented with pruritic oedematous erythema on the perioral, cheek, and eyelid areas for 5 days (Fig. 1a). The patient had worn a face mask (CampusMedico, Hiroshima, Japan) sprayed with disinfectant (Eisai Co. Ltd, To-kyo, Japan) for more than one month to protect against bacterial infection. The patient reported that the skin symptoms became aggravated after wearing the mask; therefore, we suspected contact dermatitis caused by the mask or the contents of the spray. The spray contained ethoxysilane-based quaternary ammonium salt (0.1%), ethanol (50.0%), and water (49.9%). Open patch tests for the spray (as is) or 2% ethanol were performed on the patient's lower back. The open patch test to the spray (but not to ethanol) revealed an urticarial rash with pruritus at 15 min, which disappeared within 6 h (Fig. 1b). Closed patch tests (The Finn chamber, 8.0 mm diameter, Smart Practice, Phoenix, Arizona, USA) to sterile distilled water, petroleum jelly (Vaseline ®), the mask as is, and the disinfectant product were all negative at 48 and 72 h after the patch test (results not shown), which excluded delayed-type hypersensitivity to them. The same examination was performed using 5 healthy volunteers as control, all results were negative. Therefore, we diagnosed the patient with contact urticaria due to the disinfectant sprayed on the face mask. The patient stopped using the spray and no symptoms recurred. DISCUSSION Ethoxysilane-based quaternary ammonium salt was developed in the late 2000s and has been used as a disinfectant liquid spray with bactericidal, virucidal, and fungicidal properties on masks, towels, air-conditioner filters, etc. Ethoxysilane-based quaternary ammonium salt is classified as a quaternary ammonium compound (QAC) (Fig. S1a 1). Contact dermatitis and contact ur-ticaria resulting from QACs, especially benzalkonium chloride, have been reported previously (2, 3). Possible underlying mechanisms of QACs in contact dermati-tis include immunological reaction and non-specific histamine release. It remains unclear how the patient became sensitized to ethoxysilane-based quaternary ammonium salt. It is of note that the size of ethoxysilane-based quaternary ammonium salt (Fig. S1a 1) is about 300 …
منابع مشابه
Postextubation severe bronchospasm and hypotension triggered by exposure to a disinfectant spray.
IN the perioperative period, anaphylactic reactions are often induced by the intravenous administration of muscle relaxants, antibiotics, colloids, and radiocontrast materials as well as after local contact with latexcontaining materials (e.g., gloves, catheters, airway tube) and chlorhexidine. Inhalation of toxic and highly irritant substances contained in cleaning solutions has occasionally b...
متن کاملHygienic performance evaluation and effect of training in order to confronting with the Covid-19 virus in the metal industries staff
Background and aims: Recently, the respiratory acute syndrome or Covid-19 disease has been become as one of the most important concerns in the national and global level. Covid-19 disease is caused by the virus SARS-CoV-2 or Covid-19. Covid-19 virus is spreading through saliva drops or nasal discharge when coughing or sneezing. Covid-19 disease not only has significantly negative affect on the g...
متن کاملDrag Reduction for Viscous Laminar Flow on Spray-Coated Non- Wetting Surfaces†
We estimate the effective Navier-slip length for flow over a spray-fabricated liquid-repellent surface which supports a composite solid-air-liquid interface or ’Cassie-Baxter’ state. The morphology of the coated substrate consists of randomly distributed corpuscular micro-structures which encapsulate a film of trapped air (or ’plastron’) upon contact with liquid. The reduction in viscous skin f...
متن کاملOccupational contact urticaria caused by airborne methylhexahydrophthalic anhydride.
Acid anhydrides are low-molecular weight chemicals known to cause respiratory irritancy and allergy. Skin allergy has on rare occasions been reported. A total of 3 subjects with occupational exposure to methylhexahydrophthalic anhydride (MHHPA) and hexahydrophthalic anhydride (HHPA) from an epoxy resin system were studied to evaluate the nature of their reported skin and nose complaints (work-r...
متن کاملاثر ضد میکروبی دو ماده ضد عفونی کننده بر توربین های دندانپزشکی
Statement of Problem: Rotary dental instruments (i-e. iow speed and high speed handpieces), due to infection spread high potentiality, should be sterilized between dental visits for each patient. When a high speed rotary instrument pauses at a high velocity, contaminated fluids like blood and saliva will be sucked into its tubes.Purpose: The aim of this study was to compare the bactericidal eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta dermato-venereologica
دوره 95 5 شماره
صفحات -
تاریخ انتشار 2015