Experience with a Composite Insulator Testing Instrument Based on the Electric Field Method
نویسنده
چکیده
Two large electric utilities, located on the US West Coast, use a considerable number of composite insulators on their power transmission lines. Some of these insulators may be prone to premature insulation degradation caused by poor design, manufacturing defects, pollution or construction mishandling, or gunshot vandalism. This may result in flashover and power outages, unless the state of the insulators can be evaluated periodically and the defective ones replaced in time. Also for reasons of economics, replacement of defective composite insulators is often done using bare-hand live line maintenance methods. Maintenance personnel safety can be improved if an appropriate testing method is available to determine if sufficient insulation remains in the insulator. This paper describes laboratory and field evaluation tests that were performed with a new type of insulator tester to determine if it is suitable to assess the remaining insulation level. These tests have demonstrated that conductive defects, sometimes as short as 2,5 cm (1"), and conductive pollution deposits are detectable with this type of instrument.
منابع مشابه
Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملElectric Field Analysis and Experimental Evaluation of 400 kV Silicone Composite Insulator
Abstract—In electrical power system, high voltage insulators are necessary for consistent performance. All insulators are exposed to different mechanical and electrical stresses. Mechanical stresses occur due to various loads such as wind load, hardware and conductors weight. Electrical stresses are due to over voltages and operating voltages. The performance analysis of polymer insulators is a...
متن کاملAssessing Partial Discharge on Composite Insulators Under Desert Pollution Conditions
Transmission lines located in the Sinai desert are subjected to desert climate, one of whose features, especially in the spring, is sand storms. Line insulators are thus exposed to sand contamination, which may produce streamer discharges in the air surrounding insulator surface. Such discharges may lead to flashover. This paper examines the electric field and potential distributions on sand-po...
متن کاملDielectrophoretic effect of nonuniform electric fields on the protoplast cell
In recent years, dielectrophoresis based microfluidics systems have been used to manipulate colloids, inert particles, and biological microparticles, such as red blood cells, white blood cells, platelets, cancer cells, bacteria, yeast, microorganisms, proteins, DNA, etc. In the current study the governing electric potential equations have been solved in the presence of cell for the purpose of ...
متن کاملDynamic Stability of Laminated Composite Plates with an External Smart Damper
The dynamic stability of a composite plate with external electrorheological (ER) damper subjected to an axial periodic load is investigated. Electrorheological fluids are a class of smart materials, which exhibit reversible changes in mechanical properties when subjected to an electric field. As a result, the dynamic behavior of the structure is changed. The ER damper is used for suppressing th...
متن کامل