“Proof-Of-Concept” Evaluation of an Automated Sputum Smear Microscopy System for Tuberculosis Diagnosis

نویسندگان

  • James J. Lewis
  • Violet N. Chihota
  • Minty van der Meulen
  • P. Bernard Fourie
  • Katherine L. Fielding
  • Alison D. Grant
  • Susan E. Dorman
  • Gavin J. Churchyard
چکیده

BACKGROUND "TBDx" is an innovative smear microscopy system that automatically loads slides onto a microscope, focuses and digitally captures images and then classifies smears as positive or negative using computerised algorithms. OBJECTIVES To determine the diagnostic accuracy of TBDx, using culture as the gold standard, and compare this to a microscopist's diagnostic performance. METHODS This study is nested within a cross-sectional study of tuberculosis suspects from South African gold mines. All tuberculosis suspects had one sputum sample collected, which was decontaminated prior to smear microscopy, liquid culture and organism identification. All slides were auramine-stained and then read by both a research microscopist and by TBDx using fluorescence microscopes, classifying slides based on the WHO classification standard of 100 fields of view (FoV) at 400× magnification. RESULTS Of 981 specimens, 269 were culture positive for Mycobacterium tuberculosis (27.4%). TBDx had higher sensitivity than the microscopist (75.8% versus 52.8%, respectively), but markedly lower specificity (43.5% versus 98.6%, respectively). TBDx classified 520/981 smears (53.0%) as scanty positive. Hence, a proposed hybrid software/human approach that combined TBDx examination of all smears with microscopist re-examination of TBDx scanty smears was explored by replacing the "positive" result of slides with 1-9 AFB detected on TBDx with the microscopist's original reading. Compared to using the microscopist's original results for all 981 slides, this hybrid approach resulted in equivalent specificity, a slight reduction in sensitivity from 52.8% to 49.4% (difference of 3.3%; 95% confidence interval: 0.2%, 6.5%), and a reduction in the number of slides to be read by the microscopist by 47.0%. DISCUSSION Compared to a research microscopist, the hybrid software/human approach had similar specificity and positive predictive value, but sensitivity requires further improvement. Automated microscopy has the potential to substantially reduce the number of slides read by microscopists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Value of Bronchoalveolar Lavage in the Diagnosis of Sputum Smear-NegativePulmonary Tuberculosis

Background and Objectives: Sputum smear staining for acid-fast bacilli is initial approach to the diagnosis of pulmonary tuberculosis (PTB) but more than 50% of cases are sputum smear-negative. This study was aimed to investigate the diagnostic value of fiberoptic bronchoscopy (FOB) guided bronchoalveolar lavage (BAL) in patients suspected to have tuberculosis. Methods: This prospective cross-...

متن کامل

مقایسه ارزش تشخیصی اسمیر خلط به دو روش میکروسکوپی در بیماران مشکوک به سل ریوی با و بدون استفاده ازهیپوکلریت سدیم

Background and purpose: Direct smear microscopy is the most common method of detecting tuberculosis with 70% sensitivity in best conditions, therefore, researches have always focused on improving the sensitivity of sputum smear. This study aimed at comparing the diagnostic value of sputum smear using light microscopy and fluorescence microscopy without sodium hypochlorite in patients with suspe...

متن کامل

The role of bronchiL brushing through fiber-optic bronchoscopy in rapid diagnosis of sputum smear negative cases of pulmonary tuberculosis

  The aim of this study was to determine the ability of bronchial brushing in rapid diagnosis of pulmonary tuberculosis in patients with negative sputum smear.this retrospective study was performed on 188 patients who were suspected of pulmonary tuberculosis and had undergone fiberoptic bronchoscopy during the period of 1990 to 1996 in Kerman university No.1 . Although their history, physical ...

متن کامل

Development and evaluation of an automated stainer for acid-fast bacilli.

The current strategy for the control of tuberculosis (TB) relies on early diagnosis, and smear microscopy is an essential component of the laboratory diagnosis of TB in most countries with a high prevalence of the disease. However, even simple smear microscopy examination is far from satisfactory because staining results can vary among individual technicians. In an effort to minimize variations...

متن کامل

Comparison of sensitivity and specificity of PCR and sputum smear compared to culture in diagnosis of tuberculosis

Background: Molecular detection has recently been proposed by nucleic acid amplification, known as polymerase chain reaction (PCR). The aim of this study was to compare the diagnostic method of smear and polymerase chain reaction with culture in terms of sensitivity, specificity, positive and negative predictive value in the diagnosis of pulmonary tuberculosis. Methods: In this cross-sectional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012