Retention of visible implant tags in small rockpool fishes

نویسنده

  • Shane P. Griffiths
چکیده

Retention and associated fish mortality of visible implant alphanumeric (VIA) and fluorescent elastomer tags was assessed in 2 Australian intertidal rockpool fishes, Girella elevata (Girellidae) and Bathygobius cocosensis (Gobiidae). Mean retention of VIA and elastomer tags after 90 d was 32 ± 20% and 77 ± 19%, respectively. After 90 d the fish mean mortality from VIA tags (20 ± 5%) was significantly higher than from elastomer tags (7 ± 2%) and untagged control groups (11 ± 2%). Elastomer tags appear most suitable for marking batches of fish of various size, while VIA tags appear suitable for identification of larger individuals of species such as many gobies that have adequate transparent tissue for tag recognition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Large and Small Visible Implant Tags: Retention and Readability in Hatchery Brook Trout

—Retention and readability of small (2.5 3 1.0 3 0.1-mm) and large (3.0 3 1.5 3 0.1mm) visible implant (VI) tags were compared among different size-classes (211–470 mm total length, TL) of hatchery brook trout Salvelinus fontinalis. Among smaller size-groups (,400 mm TL), retention of large tags (63–86%) 100 d after tagging was less than retention of small tags (89–97%). Overall retention of la...

متن کامل

Evaluation of visible implant elastomer tags in zebrafish (Danio rerio)

The use of the visible implant elastomer (VIE) tagging system in zebrafish (Danio rerio) was examined. Two tag orientations (horizontal and vertical) at the dorsal fin base were tested for tag retention, tag fragmentation and whether VIE tags affected growth and survival of juvenile zebrafish (1-4 month post hatch). Six tag locations (abdomen, anal fin base, caudal peduncle, dorsal fin base, pe...

متن کامل

Short-term evaluation of visible implant alpha tags in juveniles of three fish species under laboratory conditions.

Visible implant alpha (VI alpha) tag-induced changes in mortality and condition, as well as tag retention and readability, were examined during a 4-week period for juveniles of three fish species: tiger muskellunge Esox masquinongy × Esox lucius (91 ± 7 mm total length, L(T), mean ± s.d.), Snake River cutthroat trout Oncorhynchus clarki behnkei (84 ± 8 mm) and rainbow trout Oncorhynchus mykiss ...

متن کامل

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002