CUSUM: A tool for early feedback about performance?
نویسندگان
چکیده
BACKGROUND Modern day clinical practice demands evidence justifying our choice of treatment methods. Cumulative sum techniques (cusum) are amongst the simplest statistical methods known. They provide rapid analysis and identification of trends in a series of data. This study highlights use of these techniques as an early performance indicator of a clinical procedure before its implementation. METHODS Twenty consecutive patients who underwent total hip or knee arthroplasty received a simple dressing--blue gauze and Tegaderm. Cusum charting was used to assess the dressing with regards to skin blistering. At an acceptable level of performance the curve would oscillate about the horizontal axis and the overall trend therefore said to be flat. If performance is unacceptable, the cusum slopes upward. RESULTS The cusum plot for the twenty patients did not cross the specified control limits. This showed that our simple dressing met specified standards with regards to wound blistering postoperatively. CONCLUSION We recommend the use of this simple, yet versatile cusum technique in the early evaluation of a clinical procedure before its implementation.
منابع مشابه
CUSUM: a dynamic tool for monitoring competency in cataract surgery performance.
AIMS To apply cumulative sum (CUSUM) in monitoring performance of surgeons in cataract surgery and to evaluate the response of performance to intervention. METHOD A CUSUM analysis was applied to 80 phacoemulsification performed by three ophthalmic trainees and one consultant, for the occurrence of posterior capsular rupture and postoperative refracted vision of worse than 6/12 among patients ...
متن کاملContinuous monitoring of the performance of hip prostheses.
New brands of joint prosthesis are released for general implantation with limited evidence of their long-term performance in patients. The CUSUM continuous monitoring method is a statistical testing procedure which could be used to provide prospective evaluation of brands as soon as implantation in patients begins and give early warning of poor performance. We describe the CUSUM and illustrate ...
متن کاملA risk adjusted self-starting Bernoulli CUSUM control chart with dynamic probability control limits
Usually, in monitoring schemes the nominal value of the process parameter is assumed known. However, this assumption is violated owing to costly sampling and lack of data particularly in healthcare systems. On the other hand, applying a fixed control limit for the risk-adjusted Bernoulli chart causes to a variable in-control average run length performance for patient populations with dissimilar...
متن کاملEarly Detection of Meningitis Outbreaks: Application of Limited-baseline Data
Background There is no published study evaluating the performance of cumulative sum (CUSUM) algorithm on meningitis data with limited baseline period. This study aimed to evaluate the CUSUM performance in timely detection of 707 semi-synthetic outbreak days. Methods Simulated outbreaks were generated using syndromic data on fever and neurological symptoms from Mar 2010 to Mar 2013 in Hamadan ...
متن کاملA Comparison of 2-CUSUM Stopping Rules for Quickest Detection of Two-sided Alternatives in a Brownian Motion Model
This work compares the performance of all existing 2-CUSUM stopping rules used in the problem of sequential detection of a change in the drift of a Brownian motion in the case of two-sided alternatives. As a performance measure an extended Lorden criterion is used. According to this criterion the optimal stopping rule is an equalizer rule. This paper compares the performance of the modified dri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Medical Research Methodology
دوره 6 شماره
صفحات -
تاریخ انتشار 2006