Successful treatment of sternal non-union by ultrasound.
نویسندگان
چکیده
We report a case of sternal non-union after open aortic valve replacement surgery in a 48-year-old man. The sternotomy was repaired using stainless steel wires and later, 'flexigrip' cables. He presented to us six months later complaining of persistent pain in the sternotomy site. CT-scan confirmed a sternal non-union. After consultation with the ultrasound device, and aortic valve manufacturers, we established that there was no previous similar reported case, but there were no contraindications to use of ultrasound. We started treatment using non-invasive pulsed ultrasound therapy. The non-union healed clinically and radiologically within four months. This is the first report of treatment of sternal non-union using low intensity ultrasound. This therapy appears safe and can be used as a first line of treatment for adequately stabilized sternal non-unions.
منابع مشابه
Sternal nonunion on bone scintigraphy: a case report
Sternal non-union is a severe complication of sternotomy closure following open heart surgeries. Healing problems typically occur in 0.3% to 5% of patients. Technetium-99m methylene diphosphonate (99mTc-MDP) bone scintigraphy has been used to assess bone nonunion to predict the healing response for proper management. In this report, we present the case of a marked sternal nonunio...
متن کاملSupportive treatment using a compression garment vest of painful sternal instability following deep surgical wound infection: a case report
INTRODUCTION Sternal dehiscence and instability poses a significant cause of persistent pain and limited quality of life following hospital discharge for 0.2% to 5% of patients who have undergone median sternotomy for open heart surgery. We report a successful, conservative, supportive long-term therapy of painful sternal non-union using a customized compression garment vest. CASE PRESENTATIO...
متن کاملنتایج درمان شکستگیهای جوشنخورده استخوان ران به روش پلاکگذاری و گرافت استخوانی
Introduction: Close reduction and intra medullary nailing has been established as the treatment for femoral shaft fractures with a non::union:: rate of 0.9-1.1 % though, it is still controversial. Currently, the most accepted method for treatment of non ::union:: is exchange nailing. Therefore, this study aimed to investigate treatment of femoral shaft fractures non ::union:: via 2 methods of e...
متن کاملAssessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating
Abstract Background: The tibial diaphyseal fractures are the most common type of long bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia fractures have the second incidence of all tibia fractures after the middle tibia fractures. The purpose of the study was to asses...
متن کاملUltrasound- guided Hydrostatic (Hydrocolonic) Treatment of Meconium Ileus: A Preliminary Report
Background Meconium ileus (MI) is one type intestinal obstruction due to inspissated meconium at the level of the terminal ileum. The purpose of this study is to present the non-ionizing ultrasound-guided approach for the treatment of meconium ileus. Materials and Methods This study was performed, prospectively, at Dr. Sheikh and Akbar children's Hospitals, Mashhad University of Medical Science...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2009