Automated pre-column derivatization and its application to amino-acid analysis using high-performance liquid chromatography
نویسندگان
چکیده
Although chemical modification of analytes is a well-accepted adjunct to chromatography, little attention had been paid to the automation of pre-column derivatization techniques. An automated pre-column system would offer advantages when analyses are performed using labile derivatives; and also when the time between injections is long and so staff time spent on achieving maximum analytical output is less than optimal. Both of these features exist with the analysis of amino-acids in physiological samples using pre-column 0-phthalaldehyde! 2-mercaptoethanol (OPA/MCE) derivatization and reversedphase high-performance liquid chromatography (HPLC) [1]. These fluorescent derivatives are labile !-1 and 2-1 and therefore have to be prepared in a precise manner immediately before injection onto the column. A system is described for automatically sampling, derivatizing and injecting specimens onto an HPLC and analysing for amino-acids. Furthermore, this system may be operated overnightmcapitalizing on the reduced chromatographic run time when compared with amino-acid analysis using ionexchange post-column derivatization methods [3].
منابع مشابه
A Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study
Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...
متن کاملAnalysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA
ABSTRACT Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...
متن کاملValidation of the determination of amino acids in plasma by high-performance liquid chromatography using automated pre-column derivatization with o-phthaldialdehyde.
A sensitive and reproducible fully automated method for the determination of amino acids in plasma based on reversed-phase high-performance liquid chromatography and o-phthaldialdehyde pre-column derivatization is described. A 5-microns Spherisorb ODS 2 column (125 x 3 mm I.D.) was selected for routine determination. Over 40 physiological amino acids could be determined within 49 min (injection...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید