An Investigation of Atomic Structures Derived from X-ray Crystallography and Cryo-Electron Microscopy Using Distal Blocks of Side-Chains.
نویسندگان
چکیده
Cryo-electron microscopy (cryo-EM) is a structure determination method for large molecular complexes. As more and more atomic structures are determined using this technique, it is becoming possible to perform statistical characterization of side-chain conformations. Two data sets were involved to characterize block lengths for each of the 18 types of amino acids. One set contains 9131 structures resolved using X-ray crystallography from density maps with better than or equal to 1.5 Å resolutions, and the other contains 237 protein structures derived from cryo-EM density maps with 2-4 Å resolutions. The results show that the normalized probability density function of block lengths is similar between the X-ray data set and the cryo-EM data set for most of the residue types, but differences were observed for ARG, GLU, ILE, LYS, PHE, TRP, and TYR for which conformations with certain shorter block lengths are more likely to be observed in the cryo-EM set with 2-4 Å resolutions.
منابع مشابه
The structure of the aquaporin-1 water channel: a comparison between cryo-electron microscopy and X-ray crystallography.
Three different medium-resolution structures of the human water channel aquaporin-1 (AQP1) have been solved by cryo-electron microscopy (cryo-EM) during the last two years. Recently, the structure of the strongly related bovine AQP1 was solved by X-ray crystallography at higher resolution, allowing a validation of the original medium-resolution structures, and providing a good indication for th...
متن کاملNear-atomic resolution using electron cryomicroscopy and single-particle reconstruction.
Electron cryomicroscopy (cryo-EM) yields images of macromolecular assemblies and their components, from which 3D structures can be determined, by using an image processing method commonly known as "single-particle reconstruction." During the past two decades, this technique has become an important tool for 3D structure determination, but it generally has not been possible to determine atomic mo...
متن کاملProtein Conformational Changes in the Bacteriorhodopsin Photocycle: Comparison of Findings from Electron and X-Ray Crystallographic Analyses
Light-driven conformational changes in the membrane protein bacteriorhodopsin have been studied extensively using X-ray and electron crystallography, resulting in the deposition of >30 sets of coordinates describing structural changes at various stages of proton transport. Using projection difference Fourier maps, we show that coordinates reported by different groups for the same photocycle int...
متن کاملHigh Resolution Imaging of Radiation Sensitive Biological Samples
Cryo-electron microscopy has seen incredible progress recently. From the first reconstruction of frozen hydrated samples to recent atomicresolution structures, structural biology is undergoing a revolution. However, until recently, the resolution of cryo-EM structures was often significantly lower than that of X-ray crystallography. We have reached a point where, for an increasing number of sam...
متن کاملFitting atomic models into electron-microscopy maps.
Combining X-ray crystallographically determined atomic structures of component domains or subunits with cryo-electron microscopic three-dimensional images at around 22 A resolution can produce structural information that is accurate to about 2.2 A resolution. In an initial step, it is necessary to determine accurately the absolute scale and absolute hand of the cryo-electron microscopy map, the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Molecules
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2018