Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery.
نویسندگان
چکیده
OBJECTIVE The authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods. DESIGN A prospective study. SETTING Cardiac surgery intensive care unit in a teaching hospital. PARTICIPANTS Ninety-four measurements from 59 patients with ongoing high doses of inotropic drugs and/or an intra-aortic balloon pump for low-cardiac-output syndrome after cardiac surgery were studied. INTERVENTIONS The pulmonary artery catheter and the radial or femoral arterial catheter for measuring blood pressure were already in place for standard hemodynamic monitoring. MEASUREMENTS AND MAIN RESULTS The mean of the total CI measurements was 2.94 ± 0.67 L/min/m(2) with PRAM and 2.95 ± 0.63 L/min/m(2) with ThD, with no significant difference according to the linear mixed models analysis. The PRAM and ThD techniques were similar in unstable patients without atrial fibrillation (mean bias 0.047 ± 0.395 L/min/m(2) and a percentage error of 29%), while no agreement between PRAM and ThD was found in unstable patients with atrial fibrillation (mean bias 0.195 ± 0.885 L/min/m(2) and a percentage error of 69%). CONCLUSION Cardiac index measurements after cardiac surgery performed with PRAM and with ThD showed a good agreement in hemodynamically unstable patients given high doses of inotropes and/or an IABP in patients in sinus rhythm, but not in those with atrial fibrillation.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملComparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملMost Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM)
Invasive hemodynamic monitoring is a cornerstone of the care of critically ill and hemodynamically unstable patients in both intensive care units and operating rooms. The assessment of cardiac output by means of the pulmonary artery catheter has been considered the clinical gold standard. Nevertheless, several concerns have been raised regarding its invasiveness, usefulness, and associated comp...
متن کاملIncidence of pressure ulcer in patients who were admitted to open heart cardiac surgery intensive care unit
Background and aims: Cardiac surgery patients are at high risk of pressure ulcers. In the present study, we determined the incidence of pressure ulcer in patients who were admitted to open heart cardiac surgery intensive care unit and related risk factors. Methods: With using convenience sampling all the eligible patients who were admitted to Boali cardiac surgery during June to August 2015 we...
متن کاملLack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients.
BACKGROUND Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiothoracic and vascular anesthesia
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2013