Utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist devices
نویسندگان
چکیده
AIM To assess utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist device (VAD). METHODS Retrospective study of pediatric patients supported with a Berlin EXCOR VAD at a single pediatric tertiary care center during a single year. RESULTS We demonstrated associations between activated thromboplastin time (aPTT) and R-thromboelastography (R-TEG) values (rs = 0.65, P < 0.001) and between anti-Xa assay and R-TEG values (rs = 0.54, P < 0.001). The strongest correlation was seen between aPTT and anti-Xa assays (rs = 0.71, P < 0.001). There was also a statistically significant correlation between platelet counts and the maximum amplitude of TEG (rs = 0.71, P < 0.001). Importantly, there was no association between dose of unfractionated heparin and either measure of anticoagulation (aPTT, anti-Xa or R-TEG value). CONCLUSION This study suggests that while there is strong correlation between aPTT, anti-Xa assay and R-TEG values for patients requiring VAD support, there is a lack of relevant correlation between heparin dose and degree of effect. This raises concern as various guidelines continue to recommend using these parameters to titrate heparin therapy.
منابع مشابه
Ventricular Assist Devices for Pediatric Heart Disease
Mechanical Circulation Assist Devices are designed for the treatment of acute and chronic heart failure and can be applied for different indications and assist period. Treatments that are carried out with Ventricular Assist Device System (VADs) have improved over course of time, within the practical applications of pediatric cardiac surgery. Pulsatile devices being in the lead, paracorporeal as...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملBivalirudin Anticoagulation for a Pediatric Patient with Heparin-Induced Thrombocytopenia and Thrombosis Requiring Cardiopulmonary Bypass for Ventricular Assist Device Placement.
The direct thrombin inhibitor bivalirudin is an option for anticoagulation in patients with heparin induced thrombocytopenia (HIT) requiring cardiopulmonary bypass (CPB). There are a limited number of reports of pediatric patients in which bivalirudin has been used for anticoagulation for CPB. We present the case of an 11 year old male with acute onset heart failure secondary to idiopathic dila...
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کامل