Special problems in aerosol delivery: artificial airways.

نویسنده

  • R Dhand
چکیده

Several factors interact in influencing aerosol deposition during mechanical ventilation. Among these factors, the artificial airway is a significant barrier for aerosol deposition. Earlier studies overemphasized the impediments created by the artificial airway to aerosol delivery, because the aerosol generator was placed adjacent to the endotracheal tube or was connected to it. When the aerosol generator is placed away from the endotracheal tube, the fraction that deposits within the tube is reduced and greater aerosol deposition occurs in the lungs. The type of aerosol generator used and the ventilator settings have a greater effect than the size of the tube on the amount of aerosol that deposits in the artificial airway. To minimize aerosol loss within artificial airways, an endotracheal tube of the appropriate size should be selected. "Priming" the tube with a few doses of aerosol before use decreases the electrostatic charge on its walls and may reduce aerosol deposition within the tube. Similarly, using a spacer with the MDI, and placement of the combination in the inspiratory limb at a distance of at least 15 cm from the endotracheal tube reduces aerosol loss within the endotracheal tube. Use of nebulizers that produce submicronic aerosols, and placing them closer to the ventilator instead of closer to the patient also decreases aerosol impaction in the artificial airway. Use of a low inspiratory flow (30-60 L/min in adults), higher duty cycle (> 0.3), and helium-oxygen mixture instead of air or oxygen are other measures to reduce aerosol loss in the airway and thereby improve aerosol delivery to the lower respiratory tract of mechanically ventilated patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol Therapy in Pulmonary Critical Care.

Aerosolized medications are routinely used for the treatment of critically ill patients. This paper reviews aerosol delivery devices with a focus on issues related to their performance in pulmonary critical care. Factors affecting aerosol drug delivery to mechanically ventilated adults and spontaneously breathing patients with artificial airways are reviewed. Device selection, optimum device te...

متن کامل

Clinical evaluation of a simple demand inhalation MDI aerosol delivery device.

Inhalation of medication is the preferred method for treating reversible airway obstruction; however, difficulties in the use of pressurized canisters frequently lead to suboptimal results. The Aerochamber (Monoghan Medical Corp) is a portable breath-actuated device that attaches to a metered-dose inhaler (MDI) and is designed to overcome many of the problems of aerosol delivery encountered by ...

متن کامل

Special problems in aerosol delivery: neonatal and pediatric considerations.

Identification of the determinants of efficient aerosol delivery and the specific challenges of aerosol delivery to infants and children can facilitate a systematic approach to optimize aerosol delivery to this population. There are inherent anatomical, physiologic, pathophysiologic, and technical limitations of aerosol efficiency in infants and young children. Nevertheless, one can enhance aer...

متن کامل

Nebulized drug delivery in patients breathing spontaneously through an artificial airway.

During the past 25 years, incremental gains in knowledge about aerosol delivery to mechanically ventilated patients had a major impact on patient care in this setting. The complex array of factors influencing aerosol delivery during mechanical ventilation made it difficult to elucidate the contribution of individual parameters to optimal aerosol delivery. Over the ensuing years, bench models ma...

متن کامل

Inhaled Aerosol Distribution in Human Airways: A Scintigraphy-Guided Study in a 3D Printed Model.

BACKGROUND While it is generally accepted that inertial impaction will lead to particle loss as aerosol is being carried into the pulmonary airways, most predictive aerosol deposition models adopt the hypothesis that the inhaled particles that remain airborne will distribute according to the gas flow distribution between airways downstream. METHODS Using a 3D printed cast of human airways, we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2000