Biomechanical stability of intramedullary nailed high proximal third tibial fractures with cement augmented proximal screws.
نویسندگان
چکیده
OBJECTIVE Intramedullary nailing of nonarticular proximal tibia fractures can be affected by bone density resulting in loss of stability, fixation, and malalignment in osteopenic bone. This study was designed to quantify the biomechanical effects of augmenting proximal screws with cement in intramedullary nailing of high proximal third tibial fractures. DESIGN In vitro biomechanical study using anatomic specimens. METHODS Reamed nails were inserted into seven pairs of fresh-frozen cadaveric proximal tibiae and secured using two oblique and two transverse proximal screws. Paired tibiae were randomly assigned into two groups: cemented and noncemented proximal screw-holes. Bone cement was injected into the screw-holes before screw insertion in the cemented tibiae. Specimens were then tested in flexion/extension and varus/valgus to 12 Nm and in torsion to 7 Nm. Physical measurements of bone density were obtained to determine the effect of density on stability. MAIN OUTCOME MEASURES Stability of the construct in both groups was analyzed and compared statistically using paired t tests. RESULTS Cement augmentation of the proximal screws significantly increased mechanical stability in torsion and varus/valgus load configurations, with average decreases in rotational motion of 5.4 degrees +/- 1.6 degrees and 5.1 degrees +/- 5 degrees respectively. No change in stability was observed in flexion/extension loading. A trend toward decreased stability was seen in the uncemented construct in varus/valgus; cement augmentation of the proximal screws eliminated this effect. CONCLUSIONS Lower bone density decreased the stability of the uncemented construct; however, cement augmentation of the proximal screws showed a trend to eliminate this effect in the varus/valgus loading configuration and should be considered when nailing proximal third tibial fractures in osteoporotic patients.
منابع مشابه
Unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures.
PURPOSE To assess the outcome of unreamed intramedullary nailing through the lateralised entry point using oblique proximal and biplanar distal interlocking screws. METHODS 15 men and 3 women aged 25 to 58 (mean, 37) years underwent unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third metaphyseal tibial fractures. The entry point was...
متن کاملIntramedullary fixation of proximal tibial fractures
is challenging owing to the relatively high chance of displacement during nail insertion. The stability of the proximal fixation is inferior because of the wider diameter of the intramedullary canal in the metaphysis. This has led to the use of Poller screws for additional blocking during intramedullary fixation of proximal or distal tibial fractures.1 The effects of Poller screw is two-fold. F...
متن کاملThe biomechanics of varied proximal locking screw configurations in a synthetic model of proximal third tibial fracture fixation.
OBJECTIVE To determine if 1) angularly stable devices created by compressing ("locking") proximal locking screws to intramedullary nails using end caps or compression screws or 2) increasing the number of proximal screws from two to three increases the stiffness of intramedullary constructs that stabilize proximal third tibia fractures in a nonosteopenic bone model. METHODS Four proximal lock...
متن کاملTreatment of Proximal Femur Osteomyelitis Occurred after Proximal Femoral Nail Antirotation Fixation, with Antibiotic Cement-coated Tibia Intramedullary Nail: A Case Report
Antibiotic cement-coated intramedullary nails maintain a locally high antibiotic concentration while contributing to bone stability. We present a case of femoral subtrochanteric fracture in a patient with an infected nonunion who was successfully treated for an infection and nonunion using an antibiotic cement-coated tibial intramedullary nail. A 79-year-old woman with a right femoral subtrocha...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 19 7 شماره
صفحات -
تاریخ انتشار 2005