Ion Mobility Studies on the Negative Ion-Molecule Chemistry of Isoflurane and Enflurane
نویسندگان
چکیده
In the present work we present an investigation of the negative ion-molecule chemistry of the anaesthetics isoflurane, ISOF, and enflurane, ENF, in an ion mobility spectrometry/mass spectrometry (IMS/MS), in both air and nitrogen. Hexachloroethane (HCE) was introduced in both air and nitrogen to produce Cl- as a reactant ion. This study was undertaken owing to uncertainties in the chemical processes, which lead to the cluster ions reported in other work (Eiceman et al. Anal. Chem. 61, 1093-1099, 1). In particular for ISOF the product ion observed was ISOF.Cl-, and it was suggested that the Cl- was formed by dissociative electron attachment (DEA) although there was mention of a chlorine containing contaminant. We show in this study that ISOF and ENF do not produce Cl- in an IMS system either by capture of free electrons or reaction with O2-. This demonstrates that the Cl- containing ions, reported in the earlier study, must have been the result of a chlorine containing contaminant as suggested. The failure of ISOF and ENF to undergo DEA was initially surprising given the high calculated electron affinities, but further calculations showed that this was a result of the large positive vertical attachment energies (VAEs). This experimental work has been supported by electronic structure calculations at the B3LYP level, and is consistent with those obtained in a crossed electron-molecular beam two sector field mass spectrometer. An unusual observation is that the monomer complexes of ISOF and ENF with O2- are relatively unstable compared with the dimer complexes. Graphical Abstract ᅟ.
منابع مشابه
Effect of Induced Dipole-Induced Dipole Potential and the Size of Colliding Particles on Ion-Quadrupolar Molecule Collision Rate Constants
Classical trajectory (Monte Carlo) calculation is used to calculate collision rate constants of ion-quadrupolar molecule interactions for the H¯+C2H2 system. The method presented here takes into account the effect of the induced dipole-induced dipole potential on ion-quadrupolar molecule collision rate constants. It is also assumed that the colliding particles have a d...
متن کاملSpectrophotometric Studies ot Vanadium(III) Ion Complexes th p-Sulfonatocalixf 41 acme In Aqueous Solution
Spectropholornetrie technique is used to evaluate binding of the vanadium(1U) ion to a water solublecaruc[4] arene molecule in aqueous solution. On the basis of the calculated value formation constant at25rC.we found that the eomplexation of this metal on is very favored towards 25, 26, 27, 2Stetrahydroxy-5, 11, 17, 23-tetnmulphonalic acid-calix[0]areneGaussian 03 package.
متن کاملTheoretical thermodynamic study on the interaction between Fe2+ ion and Pyrazole
The interaction of Fe2+ ion with Pyrazole was theoretically studied by Gussian 03, software at HF/(LanL2DZ+6-31G) and HF/ (LanL2DZ+6-31G (d)) levels in gas phase and solution. In this study acompartion between optimized structures of Pyrazole molecule in aspect of thermodynamicparameters such as enthalpy (H°), Gibbs free energy (G°) and entropy (S°) in presence of metallic ion(Fe2+), was perfor...
متن کاملInteraction of volatile anesthetics with human Kv channels in relation to clinical concentrations.
BACKGROUND Recent evidence shows that inhibition of human Kv3 channels by intravenous anesthetics occurs at clinical concentrations. The effects of volatile anesthetics on these human ion channels are unknown. This study was designed to establish whether minimum alveolar concentrations (MAC) of halothane, enflurane, isoflurane, and desflurane exhibit effects on Kv3 channeLs. To obtain an indica...
متن کاملApplication of Ion Mobility Spectrometry for Determination of Morphine in Human Urine
In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...
متن کامل