Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer.
نویسندگان
چکیده
OBJECTIVE The objective of our study was to compare T2-weighted MRI alone and T2 combined with diffusion-weighted imaging (DWI) for the localization of prostate cancer. SUBJECTS AND METHODS T2-weighted imaging and DWI (b value = 600 s/mm2) were performed in 49 patients before radical prostatectomy using an endorectal coil at 1.5 T in this prospective trial. The peripheral zone of the prostate was divided into sextants and the transition zone into left and right halves. T2 images alone and then T2 images combined with apparent diffusion coefficient (ADC) maps (T2 + DWI) were scored for the likelihood of tumor and were compared with whole-mount histology results. Fixed window and level settings were used to display the ADC maps. Only tumors with an area of more than 0.13 cm2 (> 4 mm diameter) and a Gleason score of > or = 6 were considered significant. The area under the receiver operating characteristic curve (A(z)) was used to assess accuracy. RESULTS In the peripheral zone, the A(z) value was significantly higher (p = 0.004) for T2 plus DWI (A(z) = 0.89) than for T2 imaging alone (A(z) = 0.81). Performance was poorer in the transition zone for both T2 plus DWI (A(z) = 0.78) and T2 (A(z) = 0.79). For the whole prostate, sensitivity was significantly higher (p < 0.001) with T2 plus DWI (81% [120/149]) than with T2 imaging alone (54% [81/149]), with T2 plus DWI showing only a slight loss in specificity compared with T2 imaging alone (84% [204/243] vs 91% [222/243], respectively). CONCLUSION Combined T2 and DWI MRI is better than T2 imaging alone in the detection of significant cancer (Gleason score > or = 6 and diameter > 4 mm) within the peripheral zone of the prostate.
منابع مشابه
بررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملValue of T1/T2-weighted magnetic resonance imaging registration to reduce the postbiopsy hemorrhage effect for prostate cancer localization
BACKGROUND The aim of this study was to evaluate the value of T1/T2-weighted imaging (T1/T2WI) registration to reduce the postbiopsy hemorrhage effect for prostate cancer localization on prostate magnetic resonance imaging (MRI). METHODS Twenty-one men with pathology-proven prostate cancer who underwent preoperative MRI in a single institution were selected. The zonal anatomy was divided into...
متن کاملSignal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملProstate cancer detection in patients with total serum prostate-specific antigen levels of 4-10 ng/mL: diagnostic efficacy of diffusion-weighted imaging, dynamic contrast-enhanced MRI, and T2-weighted imaging.
OBJECTIVE The purpose of this study is to evaluate the utility of T2-weighted imaging, dynamic contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI) for detecting prostate cancer in patients with total serum prostate-specific antigen (PSA) levels of 4-10 ng/mL, which is referred to as the "gray zone." MATERIALS AND METHODS Fifty patients with gray-zone PSA levels underwent MRI...
متن کاملUsefulness of a Combined Approach of T1-Weighted, T2-Weighted, Dynamic Contrast-Enhanced, and Diffusion-Weighted Imaging in Prostate Cancer
PURPOSE We evaluated the value of a combined approach of T1-weighted (T1W) imaging, T2-weighted (T2W) imaging, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) for the detection of prostate cancer and extracapsular extension (ECE) in patients with prostate cancer by using pathologic data after radical prostatectomy. MATERIALS AND METHODS Fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 189 2 شماره
صفحات -
تاریخ انتشار 2007