Development of High Temperature Multiproperty Apparatus

نویسندگان

  • Raymond E. Taylor
  • R. E. TAYLOR
چکیده

The development of the multiproperty apparatus to include high temperature determinations of specific heat, enthalpy and thermal diffusivity in addition to the properties already measured is described. The latter properties include thermal conductivity, electrical resistivity, Lorenz ratio, total hemispherical emittance, spectral emittance at 0.65 microns and Thomson coefficient. The specific heat determination involves small transients from an established steady-state temperature. The accuracy and reproducibility of the specific heat determination is controlled by the accuracy obtained in measuring the rate of change of temperature. When photographing an oscilloscopic trace of an automatic pyrometer output, the inaccuracy was about 8 percent. By using a digital data acquisition system, it is believed that data accurate within 1 percent can be achieved at high temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging in 3D under pressure: a decade of high-pressure X-ray microtomography development at GSECARS

The high-pressure X-ray microtomography (HPXMT) apparatus has been operating at the GeoSoilEnviroCARS (GSECARS) bending magnet beamline at the Advanced Photon Source since 2005. By combining the powerful synchrotron X-ray source and fast switching between white (for X-ray diffraction) and monochromatic (for absorption imaging) modes, this technique provides the high-pressure community with a un...

متن کامل

A High Temperature, High Pressure Reaction-Screening Apparatus

This short note describes an apparatus that has been designed and constructed to allow assessment of the extent of chemical decomposition of fluids and fluid mixtures under high temperature, high pressure conditions. The apparatus is used to screen fluid systems prior to PVT (pressure-volume-temperature) or VLE (vapor-liquid equilibrium) experiments under severe conditions. For a predetermined ...

متن کامل

A high temperature apparatus for measurement of the Seebeck coefficient.

A high temperature Seebeck coefficient measurement apparatus with various features to minimize typical sources of error is designed and built. Common sources of temperature and voltage measurement error are described and principles to overcome these are proposed. With these guiding principles, a high temperature Seebeck measurement apparatus with a uniaxial 4-point contact geometry is designed ...

متن کامل

Development of Structural and Thermal Elements for Critical Dynamics in Microgravity Experiment

We report on the design, fabrication and test of cryogenic sample cells and structures for the Critical Dynamics in Microgravity Experiment (DYNAMX), an experiment scheduled to fly on the space shuttle as part of the Microgravity Science Payload (MSP) in February 2001. The design requirements for these components, and the resultant design and implementation experiences will be presented. In par...

متن کامل

کاربرد شاخص های کلروفیل فلورسنس در ارزیابی عملکرد دستگاه فتوسنتز کننده پسته خنجک (Pistacia Khinjuk L. ) تحت تنش همزمان شوری و خشکی

High temperature, high irradiance, low water vapour pressure, and lack of precipitation in most months characterize arid ecosystems. Under these conditions, trees such as pistachio suffer drought combined with salinity stress. In order to study the simultaneous effects of salinity and drought stresses on photosynthetic apparatus function in P. khinjuk, seedlings of the species were exposed to o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014