Comparison of a potentiometric and a micromechanical triglyceride biosensor.

نویسندگان

  • Renny Edwin Fernandez
  • Vemulachedu Hareesh
  • Enakshi Bhattacharya
  • Anju Chadha
چکیده

Sensitive biosensors for detection of triglyceride concentration are important. In this paper we report on two types of silicon based triglyceride sensors: an electrolyte-insulator-semiconductor capacitor (EISCAP) which is a potentiometric device and a polysilicon microcantilever. The detection principle for both sensors is based on the enzymatic hydrolysis of triglyceride though the sensing mechanisms are different: electronic for the EISCAP and mechanical for the microcantilever. The characteristics and performances of the two sensors are critically compared. The EISCAP sensor necessitates the presence of a buffer for stable measurements which limits the sensitivity of the sensor at low concentrations of the bioanalyte to 1mM. The cantilever sensor works without a buffer which improves the lower level of sensitivity to 10 microm. Both sensors are found to give reproducible and reliable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array

In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...

متن کامل

Galvanostatic Entrapment of Penicillinase into Polytyramine Films and its Utilization for the Potentiometric Determination of Penicillin

A sensitive and reliable potentiometric biosensor for determination of penicillin has been developed by exploiting the self-limiting growth of the non-conducting polymer, polytyramine. Optimum polytyramine-penicillinase (PTy-PNCnase) films for potentiometric detection of penicillin were accomplished with monomer solutions which contained 0.03 M tyramine, 37 U/mL penicillinase, 0.01 M KNO3, and ...

متن کامل

Development of a monoclonal antibody based potentiometric biosensor for terbuthylazine detection

In the present paper a new potentiometric biosensor for terbuthylazine (TBA, a herbicide widely utilized in agriculture) suitable for this determination in water samples is shown. As previously described, monoclonal antibody (mAb) showing high specificity for the analyte was utilized as biological element to perform the biosensor assay. A light addressable potentiometric sensor (LAPS), measurin...

متن کامل

Dual amperometric–potentiometric biosensor detection system for monitoring organophosphorus neurotoxins

A dual-transducer flow-injection biosensor detection system for monitoring organophosphorus (OP) neurotoxins is described. Such simultaneous use of different physical transducers in connection to the same (organophosphorous hydrolase (OPH)) enzyme enhances the information content and provides discrimination between various subclasses of OP compounds. While the potentiometric biosensor responds ...

متن کامل

Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate

A novel method for the rapid modification of fullerene for subsequent enzyme attachment to create a potentiometric biosensor is presented. Urease was immobilized onto the modified fullerene nanomaterial. The modified fullerene-immobilized urease (C60-urease) bioconjugate has been confirmed to catalyze the hydrolysis of urea in solution. The biomaterial was then deposited on a screen-printed ele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2009