Recovery of spiked troponin I in four routine assays
نویسندگان
چکیده
INTRODUCTION This study aimed to examine the recovery of spiked human cardiac troponin I (cTnI) results measured by four routine assays, and investigate possible interference from microclots. MATERIALS AND METHODS 457 consecutive samples with cTnI concentration below limit of quantitation (12 ng/L), declared by the Vitros TnI ES assay (reference assay), were measured on Beckman Coulter Accu TnI+3, Siemens TnI-Ultra and Roche TnI STAT assays. These samples were enriched with native full-length cTnI to a concentration of 100 ng/L and retested. A post-spiking result that exceeded the critical difference at a predefined probability of 0.0005 of the target concentration (the median post-spiking result for each individual assay) was considered as outlier. To determine whether microclots were a significant cause of critically discrepant outlier results, a separate 50 samples were centrifuged twice between two post-spiking measurements using the Vitros TnI ES assay. RESULTS The median recovery of the enriched cTnI was highest with the Roche assay (271 ng/L) and lowest with the Vitros assay (29 ng/L). The Vitros assay had the highest percentage of results that exceeded the critical difference (49%), followed by the Siemens (38%), Roche (18%) and Beckman Coulter (7%) assays. None of the 50 additional samples produced a critically lower cTnI result after re-centrifugation. CONCLUSIONS Our findings underscored the variability of cTnI assays in measuring native cTnI. The lack of cTnI results that became significantly lower after re-centrifugation suggested that microclots are unlikely to be a major cause of the outlier results.
منابع مشابه
Extensive troponin I and T modification detected in serum from patients with acute myocardial infarction.
BACKGROUND Cardiac troponin I and T (cTnI and cTnT) are specific biochemical serum markers for acute myocardial infarction (AMI). However, cTnI diagnostic assays are plagued by difficulties, resulting in >/=20-fold differences in measured values. These discrepancies may result from the release of the numerous cTnI modification products that are present in ischemic myocardium. The resolution of ...
متن کاملExtensive Troponin I and T Modification Detected in Serum From Patients With Acute Myocardial Infarction
Background—Cardiac troponin I and T (cTnI and cTnT) are specific biochemical serum markers for acute myocardial infarction (AMI). However, cTnI diagnostic assays are plagued by difficulties, resulting in $20-fold differences in measured values. These discrepancies may result from the release of the numerous cTnI modification products that are present in ischemic myocardium. The resolution of th...
متن کاملTroponin-specific autoantibody interference in different cardiac troponin I assay configurations.
BACKGROUND Autoantibodies to cardiac troponins (cTnAAb) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays. The aim of this study was to explore the degree of cTnAAb interference in different cTnI assay configurations. METHODS Ternary troponin complex was added into samples (serum or plasma, n = 132, 68% cTnAAb positive) from individuals without known cardiac cond...
متن کاملTime-dependent instability of cardiac troponins in human plasma spiked with NIST reference material 2921.
An important prerequisite for guaranteeing comparability of results among cardiac troponin I (cTnI) assays is the availability of a reference system, including a secondary, matrix-based reference material (1 ). Presently only the NIST Standard Reference Material (SRM) 2921 is available (2 ). This purified primary material has partial commutability characteristics, making it inadequate for direc...
متن کاملGRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کامل