Pedicle screw versus hybrid instrumentation in adolescent idiopathic scoliosis

نویسندگان

  • Ming Luo
  • Ning Li
  • Mingkui Shen
  • Lei Xia
چکیده

BACKGROUND Incidence of complications and reoperations between pedicle screw (PS) and hybrid instrumentations (HI) are still controversial in adolescent idiopathic scoliosis (AIS) patients. A systematic review and meta-analysis were performed to compare overall complications, reoperations, and radiographic outcomes between the 2 constructs. METHODS Strictly followed the PRISMA 2009 guidelines, the MEDLINE, EMBASE, and the Cochrane Library databases were used to search for literatures up to April 2016, addressing PS versus HI in AIS patients. The Newcastle-Ottawa scale was adopted to assess the quality of the studies. Data on complications, reoperations, Cobb angle of major curve, thoracic kyphosis, and proximal junctional measurement were extracted from the included studies. RevMan 5.3 and SPSS 21.0 were used for statistical analysis. RESULTS Twenty-four case-control studies with a total of 3042 AIS patients (1582 PS, 1460 HI) were included, consisting of 1 randomized controlled trial, 1 prospective study, and 22 retrospective studies. Decreased overall complications (95% CI 0.42-0.87, P = .007; I = 38%) and reoperations (95% CI 0.22-0.62, P = .0001; I = 0%) were found in PS group compared with HI group. As regard to reasons for reoperations, increased incidence of pseudarthrosis (P = .005), dislodged instrumentation (P = .005), and deep infection (P = .016) occurred in HI group. PS group achieved a better coronal correction (95% CI -7.06 to -4.54, P < .00001; I = 34%), but HI group was more powerful in restoring thoracic kyphosis (95% CI -7.88 to -3.70, P < .00001; I = 60%), and no significant differences were found in proximal junctional measurement (95% CI -0.88 to 1.54, P = .59; I = 0%) between the 2 constructs. CONCLUSION Compared with hybrid instrumentation, pedicle screw construct provides better coronal correction but less thoracic kyphosis restoring, with decreased incidence of overall complications and reoperations in AIS patients. As regard to the pedicle screw construct, the most common reasons for reoperation are malposition, deep infection, pseudarthrosis, and prominent implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pedicle screw versus hybrid construct instrumentation in adolescent idiopathic scoliosis: meta-analysis of thoracic kyphosis.

STUDY DESIGN A quantitative meta-analysis was conducted on publishing studies reporting results of spinal surgery in adolescent idiopathic scoliosis with instrumentation of pedicle screw or hybrid construct. OBJECTIVE The primary objective is to get overview of the power to restore thoracic kyphosis using 2 different instrumentations. SUMMARY OF BACKGROUND DATA During the past years, surger...

متن کامل

Morbidity and radiographic outcomes of severe scoliosis of 90° or more: a comparison of hybrid with total pedicle screw instrumentation

OBJECTIVES Untreated severe scoliosis is associated with increased mortality and remains a significant surgical challenge. Few studies have reported mortality after the surgical treatment of severe scoliosis beyond a 2-year follow-up. The objectives of this study were to evaluate mortality beyond standard 2-year follow-up and compare radiographic outcomes using hybrid or pedicle screw instrumen...

متن کامل

Three-Dimensional Correction in Patients With Lenke 1 Adolescent Idiopathic Scoliosis: Comparison of Consecutive Versus Interval Pedicle Screw Instrumentation.

STUDY DESIGN A retrospective-matched cohort study. OBJECTIVE To assess the correction of the adolescent idiopathic scoliosis (AIS) deformity in three dimensions, comparing consecutive and interval pedicle screw (PS) instrumentation techniques. SUMMARY OF BACKGROUND DATA The number of the sites that should be implanted with pedicle screws in AIS surgery is controversial. Coronal and sagittal...

متن کامل

Posterior spinal arthrodesis for adolescent idiopathic scoliosis using pedicle screw instrumentation: does a bilateral or unilateral screw technique affect surgical outcome?

We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the cor...

متن کامل

Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis

BACKGROUND The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. METHODS We ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017