Evolutive algorithms for beat-by-beat estimation of left ventricular mechanics.

نویسندگان

  • Mauro Grigioni
  • Carla Daniele
  • Umberto Morbiducci
  • Giacomo Di Benedetto
  • Giuseppe D'Avenio
  • Costantino Del Gaudio
  • Mara Abbate
  • Vincenzo Barbaro
چکیده

Traditional methods to evaluate the ventricular mechanics need intraventricular pressure and volume recordings for multiple variably loaded beats. To do this, a complex and invasive procedure must be applied, that may decrease the clinical use. To overcome this limitation, a method to estimate the ventricular mechanics beat-by-beat is presented, modeling the ventricular pressure-volume relationship with a time-varying elastance function. The ability of the genetic algorithms (GAs) as identification technique is exploited. Applying GAs on surrogated data simulating variably loading conditions, the parameters of the time-varying elastance function, considered a measure of the contractility of the myocardial fibers are identified. These single-beat estimates are highly correlated with the end systolic pressure-volume relationship slope obtained by conventional multiple-beat analysis. The main advantage in using GAs for single beat analysis may lie, in the perspective of an use for in vivo investigations, both in their stochastic nature, and in the guaranteed better performance with respect to other search techniques on problems involving noisy signals. Future studies will approach the reduction in GAs computational costs, for a real time in vivo application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beat-to-beat Left Ventricular Performance

The feasibility, accuracy and reproducibility of continuous beat-to-beat evaluation of left ventricular performance with a computerized nonimaging scintillation probe was assessed in 71 patients. This portable instrument has enough sensitivity to generate a real-time relative left ventricular volume curve using the labeled equilibrium blood pool without electrocardiographic gating. The probe wa...

متن کامل

Left ventricular function depends on previous beat ejection but not previous beat pressure load.

Previous beat contraction history, in which the performance of the left ventricle on any one beat is influenced by the mechanical events of the previous beat, may be important in the beat-to-beat regulation of left ventricular performance in the intact cardiovascular system. Prior studies of this phenomenon have established that mechanical events of the previous beat influence the function of t...

متن کامل

Previous Beat Ejection but Not Previous Beat Pressure Load

Previous beat contraction history, in which the performance of the left ventricle on any one beat is influenced by the mechanical events of the previous beat, may be important in the beat-to-beat regulation of left ventricular performance in the intact cardiovascular system. Prior studies of this phenomenon have established that mechanical events of the previous beat influence the function of t...

متن کامل

Left ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.

OBJECTIVE To assess independent determinants of beat to beat variation in left ventricular performance during atrial fibrillation. DESIGN Prospective study. SETTING University hospital. PATIENTS Seven patients with chronic non-valvar atrial fibrillation. INTERVENTIONS Invasive and non-invasive haemodynamic variables were assessed using a non-imaging computerised nuclear probe, a balloon...

متن کامل

Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance.

BACKGROUND Real-time 3-dimensional echocardiography (RT3DE) is superior to 2D echocardiography in assessing left ventricular (LV) volumes and ejection fraction (EF), but its feasibility is limited by multibeat acquisition, which requires an optimal breath-hold and a regular heart rhythm. We sought to evaluate the accuracy and feasibility of single- and 2-beat RT3DE for LV volume and EF assessme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annali dell'Istituto superiore di sanita

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2004