Comparison of Marginal Circumference of Two Different Pre-Crimped Stainless Steel Crowns for Primary Molars After Re-Crimping
نویسندگان
چکیده
OBJECTIVES It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs) for the primary maxillary and mandibular first and second molars following re-crimping. MATERIALS AND METHODS This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA. RESULTS The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P<0.001). CONCLUSION Considering the significant reduction in the marginal circumference of precrimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping.
منابع مشابه
بررسی میزان تغییر محیط و ضخامت لبه روکشهای استنلس استیل از پیش فرم گرفته (Precrimped)، بعد از Recrimping
Background and Aim: The need for recrimping precrimped stainless steel crowns by the dentist in clinic is controversial. This study aimed to evaluate the rate of marginal circumference and marginal thickness change of precrimped stainless steel crowns after recrimping. Materials and Methods: In this experimental study, 30 primary photos were taken from margins of 30 S.S.Cs (3M, Ni-Cr) related t...
متن کاملEffect of Glass Ionomer and Polycarboxylate Cements on Gingival Health of Primary Molars Restored with Stainless Steel Crown
Introduction: Glass ionomer and polycarboxylate cement have different effects on the marginal seal, microleakage, pulp tissue stimulation, and gingival health. The purpose of this study was to assess the effect of these cement on the gingival health of primary molars restored with stainless steel crowns (SSC). Methods: A total number of 34 children were selecte...
متن کاملRetention of veneered stainless steel crowns on replicated typodont primary incisors: an in vitro study.
PURPOSE The purpose of this in vitro study was to determine the effect of crimping and cementation on retention of veneered stainless steel crowns. METHODS One hundred twenty crowns, 90 from 3 commercially available brands of veneered stainless steel crowns (Dura Crown, Kinder Krown, and NuSmile Primary Crown) and 30 (plain) Unitek stainless steel crowns were assessed for retention. An orthod...
متن کاملMarginal adaptation of stainless steel crowns.
The chief goal of full coronal restoration using preformed stainless steel crowns (SSC) is replication of normal crown form and function. Marginal adaptation of SSCs involves appropriate crown size selection, trimming the crown form to achieve proper length, crimping crown edges to proximate the prepared tooth, and finishing and polishing the crown form. This report about SSC restoration focuse...
متن کاملAbsorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns
Objective. The purpose of this study was to analyze the absorption of metal ions released from stainless steel crowns by root surface of primary molars. Study Design. Laboratory research: The study included 34 primary molars, exfoliated or extracted during routine dental treatment. 17 molars were covered with stainless-steel crowns for more than two years and compared to 17 intact primary molar...
متن کامل