Aerosol Optical Depth measurements at 340 nm with a Brewer spectrophotometer and comparison with Cimel sunphotometer observations at Uccle, Belgium
نویسنده
چکیده
The Langley Plot Method (LPM) is adapted for the retrieval of Aerosol Optical Depth (AOD) values at 340 nm from Brewer#178 sun scan measurements between 335 and 345 nm (convoluted with the band pass function of the Cimel sunphotometer filter at 340 nm) performed in Uccle, Belgium. The use of sun scans instead of direct sun measurements simplifies the comparison of the AOD values with quasi-simultaneous Cimel sunphotometer values. Also, the irradiance at 340 nm is larger than the one at 320.1 nm due to lower ozone absorption, thus improving the signal to noise ratio. For the selection of the cloudless days (from now on referred to as calibration quality clear days), a new set of criteria is proposed. With the adapted method, individual clear sky AOD values, for which the selection criteria are also presented in this article, are calculated for a period from September 2006 until the end of August 2010. These values are then compared to quasi-simultaneous Cimel sunphotometer measurements, showing a very good agreement (the correlation coefficient, the slope and the intercept of the regression line are respectively 0.974, 0.968 and 0.011), which proves that good quality observations can be obtained from Brewer sun scan measurements at 340 nm. The analysis of the monthly and seasonal Brewer AODs at Uccle is consistent with studies at other sites reporting on the seasonal variation of AODs in Europe. The highest values can be observed in summer and spring, whereas more than 50% of the winter AODs are lower than 0.3. On a monthly scale, the lowest AOD are observed in December and the highest values occur in June and April. No clear weekly cycle is observed for Uccle. The current cloud-screening algorithm is still an issue, Correspondence to: V. De Bock ([email protected]) which means that some AOD values can still be influenced by scattered clouds. This effect can be seen when comparing the calculated monthly mean values of the Brewer with the AERONET measurements.
منابع مشابه
AOD intercomparisons between Brewer and CIMEL in the UV
Intercomparison of aerosol optical depth from Brewer ozone spectrophotometers and CIMEL sunphotometers measurements A. Cheymol, L. Gonzalez Sotelino, K. S. Lam, J. Kim, V. Fioletov, H. De Backer, and A. M. Siani Royal Meteorological Institute of Belgium, Department of Observations, Avenue Circulaire 3, 1180 Brussels, Belgium Hong Kong Polytechnic Univ., Department of Civil and Structural Engine...
متن کاملComparison of UV irradiances from Aura/Ozone Monitoring Instrument (OMI) with Brewer measurements at El Arenosillo (Spain) – Part 1: Analysis of parameter influence
The main objective of this study is to compare the erythemal UV irradiance (UVER) and spectral UV irradiances (at 305, 310 and 324 nm) from the Ozone Monitoring Instrument (OMI) onboard NASA EOS/Aura polar sun-synchronous satellite (launched in July 2004, local equator crossing time 01:45 p.m.) with ground-based measurements from the Brewer spectrophotometer #150 located at El Arenosillo (South...
متن کاملIntercomparison of aerosol optical depth from Brewer ozone spectrophotometers and CIMEL sunphotometers measurements
1 Royal Meteorological Institute of Belgium, Department of Observations, Avenue Circulaire 3, 1180 Brussels, Belgium 2 Hong Kong Polytechnic Univ., Department of Civil and Structural Engineering, Hong Kong 3 Yonsei Univ., Rm. 545, Global Environment Laboratory, Department of Atmospheric Science, College of Science, 134 Sinchon-dong, Seodaemoon-gu, Seoul 120-745, Republic of Korea 4 Environment ...
متن کاملDirect spectral measurements with a Brewer spectroradiometer: absolute calibration and aerosol optical depth retrieval.
We present three different methods for the absolute calibration of direct spectral irradiances measured with a Brewer spectroradiometer, which are shown to agree to within +/- 2%. Direct irradiance spectra derived by Brewer and Bentham spectroradiometers agree to within 4 +/- 3%. Good agreement was also found by a comparison of the aerosol optical depth and Angstrom exponent retrieved by the tw...
متن کاملNASA LaRC airborne high spectral resolution lidar aerosol measurements during MILAGRO: observations and validation
The NASA Langley Research Center (LaRC) airborne High Spectral Resolution Lidar (HSRL) measures vertical profiles of aerosol extinction, backscatter, and depolarization at both 532 nm and 1064 nm. In March of 2006 the HSRL participated in the Megacity Initiative: Local and Global Research Observations (MILAGRO) campaign along with several other suites of instruments deployed on both aircraft an...
متن کامل