Migration of implanted markers for image‐guided lung tumor stereotactic ablative radiotherapy

نویسندگان

  • Julian C. Hong
  • Neville C.W. Eclov
  • Yao Yu
  • Aarti K. Rao
  • Sonja Dieterich
  • Quynh‐Thu Le
  • Maximilian Diehn
  • Daniel Y. Sze
  • Billy W. Loo
  • Nishita Kothary
  • Peter G. Maxim
چکیده

The purpose of this study was to quantify postimplantation migration of percutaneously implanted cylindrical gold seeds ("seeds") and platinum endovascular embolization coils ("coils") for tumor tracking in pulmonary stereotactic ablative radiotherapy (SABR). We retrospectively analyzed the migration of markers in 32 consecutive patients with computed tomography scans postimplantation and at simulation. We implanted 147 markers (59 seeds, 88 coils) in or around 34 pulmonary tumors over 32 procedures, with one lesion implanted twice. Marker coordinates were rigidly aligned by minimizing fiducial registration error (FRE), the root mean square of the differences in marker locations for each tumor between scans. To also evaluate whether single markers were responsible for most migration, we aligned with and without the outlier causing the largest FRE increase per tumor. We applied the resultant transformation to all markers. We evaluated migration of individual markers and FRE of each group. Median scan interval was 8 days. Median individual marker migration was 1.28 mm (interquartile range [IQR] 0.78-2.63 mm). Median lesion FRE was 1.56 mm (IQR 0.92-2.95 mm). Outlier identification yielded 1.03 mm median migration (IQR 0.52-2.21 mm) and 1.97 mm median FRE (IQR 1.44-4.32 mm). Outliers caused a mean and median shift in the centroid of 1.22 and 0.80 mm (95th percentile 2.52 mm). Seeds and coils had no statistically significant difference. Univariate analysis suggested no correlation of migration with the number of markers, contact with the chest wall, or time elapsed. Marker migration between implantation and simulation is limited and unlikely to cause geometric miss during tracking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of percutaneously implanted markers for lung stereotactic radiotherapy

The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided by computed tomography (CT). Deep inspiration breath-hold CT scans (BHCT) were acquired at planning and o...

متن کامل

Non-surgical treatment of lung cancer: personalised stereotactic ablative radiotherapy.

Stereotactic ablative radiotherapy has emerged as a standard treatment for medically inoperable stage I non-small-cell lung cancer and selected cases of lung metastasis. Techniques to freeze or limit tumour movement during treatment and image-guided radiation delivery are integral to a successful stereotactic ablative treatment without overdose of surrounding normal structures. In this article,...

متن کامل

Minimal Inter-Fractional Fiducial Migration during Image-Guided Lung Stereotactic Body Radiotherapy Using SuperLock Nitinol Coil Fiducial Markers

OBJECTIVES Stereotactic body radiotherapy (SBRT) is being increasingly used for the treatment of patients with lung cancer or lung metastasis who are medically unfit to undergo resection. In order to improve accuracy and confidence in targeting tumors, many centers rely on fiducial implantation. We evaluated the migration of a novel fiducial marker specifically designed for lung tissue implante...

متن کامل

Response to stereotactic ablative radiotherapy in a novel orthotopic model of non-small cell lung cancer

Stereotactic ablative radiotherapy (SABR) is the main treatment for inoperable early-stage non-small cell lung cancer (NSCLC). Despite the widespread use of SABR, the biological determinants of response to SABR remain poorly investigated. We developed an orthotopic NSCLC animal model to study the response to clinically-relevant doses of SABR. Image-guided intra-thoracic injection of NSCLC cells...

متن کامل

Image-guided prostate radiotherapy: analysis of inter- fractional setup errors

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...