IDENTIFICATION OF LEFT VENTICULAR MODEL PARAMETERS Herman
نویسنده
چکیده
Simulations with a model of left ventricular pressure generation consisting of time varying Elastance, Resistance, Series-Elastance and Deactivation were fitted to pressure curves measured in the isolated rabbit ventricle. For constant ejection flows a fit with a RMS error of 2.78 mmHg was obtained provided that deactivation was actually incorporated in the model. Deactivation was assumed to depend linearly on end ejection pressure. Resistance was found t o be independent of volume. INTRODUCTION It has been shown that for constant ejection flow the left ventricle can be described by an Elastance E t ) [l], a Resistance R(t) [2], a Series-Elastance Es(t) [3\ and a Deactivation [4], interpreted as a time varying parallel elastance Ed(t). The time variances in the parameters appear to obey: Thus a common time function f(t) is involved, which corresponds to the time course of isovolumic pressure. The validity of this model has been derived from different and restricting experiments specifically adapted to measurement of the respective parameters. In this paper we address the question whether the complete model can accurately and non-redundantly describe ventricular pressure before, during and after constant flow ejection. Thus model simulations are fitted to experimental pressure curves, and model parameters are collectively identified. THEORY The abovef ive lement model is sinulakd.by numerically solving the finite difference equation Ve( t )-Ve( t -A t ) +re + rs V e ( t ) . A t = y 7s [V(t)-Vd].At P r (1) Where V(t) is ventricular volume, Ve(t) the volume of the elastance compartment and At is the time difference used. Vd is residual volume. Ftesistance p is admittedly volume dependent: where t m is time of end ejection. Ventricular pressure is given by d t l V ) ?sy,.f(t). [V(t)-Ve(t) -vd] (3) At end ejection Elastance is deactivated by a factor a (51) which has been shown [4] to be equal to
منابع مشابه
Post-infarction left venticular free wall rupture.
We report four cases of subacute left ventricular free wall rupture after myocardial infarction successfully treated with emergency surgery. Some aspects dealing with clinical presentation, diagnosis and treatment are discussed.
متن کاملThe Identification of the Modal Parameters of Orbital Machines using Dynamic Structural Approach
The researcher measured the least number of frequency response functions required for the identification of modal parameters, in order to simplify the identification of modal properties of such systems. In this work, the orbital machines are supposed to be a combination of orbital and non-orbital components. Structural Approach specified the identification of dynamic properties only to those ph...
متن کاملMeasurement of ventricular volume in man.
SINCE THE INITIAL observations of William Harvey and the physiologic studies of Ernest Starling, the importance of changes in volume in the ventricles of the heart has been recognized. In physiologic and clinical studies of the heart, measurements of chamber pressure and cardiac output have been more easily obtained than volume, and only in recent years have methods been developed for the estim...
متن کاملMeasurement of Ventricular Volume in Man
SINCE THE INITIAL observations of William Harvey and the physiologic studies of Ernest Starling, the importance of changes in volume in the ventricles of the heart has been recognized. In physiologic and clinical studies of the heart, measurements of chamber pressure and cardiac output have been more easily obtained than volume, and only in recent years have methods been developed for the estim...
متن کاملNonlinear Parametric Identification of an IPMC Actuator Model
Ionic polymer metal composite is a class of electro-active polymers which are very attractive smart actuators due to its large bending deflection, high mechanical flexibility, low excitation voltage, low density, and ease of fabrication. These properties make IPMC a proper candidate for many applications in various fields such as robotics, aerospace, biomedicine, etc. Although the actuation beh...
متن کامل