Evaluation of the four-hour rapid 20E system for identification of members of the family Enterobacteriaceae.
نویسندگان
چکیده
A study was conducted to compare the API Rapid 20E 4-h system (API System S.A., France; commercially available in the U.S.A. under the name DMS Rapid E System; DMS Laboratories, Darts Mill, Flemington, N.J.), the API 20E 18- to 24-h system (Analytab Products, Plainview, N.Y.), and a conventional media system to measure the ability of each to identify members of the family Enterobacteriaceae. Comparison tables rather than simple percentage agreement tables were generated to define the particular strengths and weaknesses of each system and to allow the laboratory to best use the data. The Rapid 20E compared quite favorably with conventional media. It yielded correct identifications with 95.9% of the isolates tested (API 20E, 98% identification rate). In 2.5% of the isolates, the Rapid 20E gave only genus identifications, and in 1.4% the organisms did not correspond to any key in the code book and could not be identified by the manufacturer's computer service. The ease of inoculation and the 4-h capability make the Rapid 20E system an extremely attractive development in the field of bacterial identification.
منابع مشابه
Four hour identification of Enterobacteriaceae with the API Rapid 20E and Micro-ID systems.
One hundred strains of Enterobacteriaceae were examined in parallel with the API Rapid 20E and Micro-ID commercial four hour identification systems. With the API Rapid 20E system 78% of the strains were correctly identified, 15% were not identified, and 7% were misidentified. The respective figures with the Micro-ID system were 74%, 11%, and 15%.
متن کاملCollaborative evaluation of the Radiometer Sensititre AP80 for identification of gram-negative bacilli.
A multicenter trial of the Sensititre AP80 panel read on the Sensititre AutoReader (Radiometer America, Westlake, Ohio) for the automated identification of gram-negative bacilli was conducted with 1,023 clinical isolates (879 members of the family Enterobacteriaceae plus 144 nonenteric organisms). Assignment of taxa was based on the computer-assisted interpretation of the results of a series of...
متن کاملClinical laboratory evaluation of the automicrobic system Enterobacteriaceae biochemical card.
The AutoMicrobic System Enterobacteriaceae Biochemical Card (AMS-EBC; Vitek Systems, Inc.) was evaluated in two clinical microbiology laboratories. A total of 502 consecutive clinical isolates representing members of the family Enterobacteriaceae were tested in parallel with the AMS-EBC, API 20E, and Enterotube II systems. Discrepancies between systems were resolved with the conventional method...
متن کاملRapid identification of Enterobacteriaceae with the micro-ID system versus API 20E and conventional media.
The Micro-ID system for rapid (4 h) identification of Enterobacteriaceae was evaluated by testing 433 enteric bacilli and 9 other gram-negative bacilli. Each isolate was identified with conventional tubed media and was also tested in the Micro-ID and API 20E systems. The overall accuracy of both systems was 97%. Micro-ID tests for the Voges-Proskauer reaction, indole and H2S production, and orn...
متن کاملRapid identification of Enterobacteriaceae by using noncommercial micro-tests in conjunction with API 20E profile data.
A total of 371 (97%) of 382 strains of Enterobacteriaceae representing 26 species were identified cheaply, accurately, and rapidly by using a test system based upon standard 96-well microdilution plates and the API 20E profile data.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 20 1 شماره
صفحات -
تاریخ انتشار 1984