Computational modeling of distal protection filters.
نویسندگان
چکیده
PURPOSE To quantify the relationship between velocity and pressure gradient in a distal protection filter (DPF) and to determine the feasibility of modeling a DPF as a permeable surface using computational fluid dynamics (CFD). METHODS Four DPFs (Spider RX, FilterWire EZ, RX Accunet, and Emboshield) were deployed in a single tube representing the internal carotid artery (ICA) in an in vitro flow apparatus. Steady flow of a blood-like solution was circulated with a peristaltic pump and compliance chamber. The flow rate through each DPF was measured at physiological pressure gradients, and permeability was calculated using Darcy's equation. Two computational models representing the RX Accunet were created: an actual representation of the filter geometry and a circular permeable surface. The permeability of RX Accunet was assigned to the surface, and CFD simulations were conducted with both models using experimentally derived boundary conditions. RESULTS Spider RX had the largest permeability while RX Accunet was the least permeable filter. CFD modeling of RX Accunet and the permeable surface resulted in excellent agreement with the experimental measurements of velocity and pressure gradient. However, the permeable surface model did not accurately reproduce local flow patterns near the DPF deployment site. CONCLUSION CFD can be used to model DPFs, yielding global flow parameters measured with bench-top experiments. CFD models of the detailed DPF geometry could be used for "virtual testing" of device designs under simulated flow conditions, which would have potential benefits in decreasing the number of design iterations leading up to in vivo testing.
منابع مشابه
Filters to prevent distal embolization during coronary artery stenting: the risk of mousetrap.
We describe a case of acute coronary syndrome treated with percutaneous intervention using a distal protection system that was complicated by filter entrapment into the stent struts. We discuss the advantages and concerns of distal protection and suggest some technical aspects to take into account when dealing with filter protection systems.
متن کاملDirect Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography
OBJECTIVE Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filt...
متن کاملCerebral protection during carotid artery stenting: collection and histopathologic analysis of embolized debris.
BACKGROUND AND PURPOSE Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. METHODS Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery prese...
متن کاملOutflow protection filters during percutaneous recanalization of lower extremities' arterial occlusions: a pilot study.
PURPOSE Filter devices are already employed for the protection of carotid, coronary and renal distal vascular bed during endovascular procedures. This is a pilot study investigating their feasibility, safety and distal emboli protection capability during recanalization of lower extremities' acute and subacute occlusions. MATERIALS AND METHODS Study population included 16 patients, 11 with a s...
متن کاملIMPLEMENTATION OF EXTENDED KALMAN FILTER TO REDUCE NON CYCLO-STATIONARY NOISE IN AERIAL GAMMA RAY SURVEY
Gamma-ray detection has an important role in the enhancement the nuclear safety and provides a proper environment for applications of nuclear radiation. To reduce the risk of exposure, aerial gamma survey is commonly used as an advantage of the distance between the detection system and the radiation sources. One of the most important issues in aerial gamma survey is the detection noise. Various...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2010