چکیده

BACKGROUND The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. METHODS The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. RESULTS Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. CONCLUSIONS Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Fuzzy gain scheduling of PID controller for stiction compensation in pneumatic control valve

Inherent nonlinearities like, deadband, stiction and hysteresis in control valves degenerate plant performance. Valve stiction standouts as a more widely recognized reason for poor execution in control loops. Measurement of valve stiction is essential to maintain scheduling. For industrial scenarios, loss of execution due to nonlinearity in control valves is an imperative issue that should be t...

متن کامل

Electrical Energy Storage on the Hybrid Grid of Renewable Energy System Using Fuzzy Controller Optimization Algorithm

The main risks of arising from the using fossil fuels can be referred to environmental pollution, the effects of greenhouse gases, climate change and acid rain. For this reason, efficient use of energy in economic development has always been considered as an important goal of sustainable development. In this study, the effects of time-varying electricity prices in the energy storage components ...

متن کامل

National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.

The Association for the Advancement of Medical Instrumentation develops voluntary standards for medical devices so that manufacturers might provide information on their product and basic safety and performance criteria that should be considered in qualifying the instrument for clinical use. American national standards are generated through a consensus process by committees consisting of experts...

متن کامل

Optimal Location and Parameter Settings of UPFC Device in Transmission System based on Imperialistic Competitive Algorithm

In this paper, we present a new method to determine the optimal location and parameter settings of UnifiedPower Flow Controller (UPFC) for removing voltage violations and transmission lines overloading. UPFC isconsidered as the most powerful member of the FACTS devices, that it can control shunt and series power flow.This option gives to UPFC the power to control the voltage profile and transmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016