Evaluation of surface topography changes in three NiTi file systems using rotary and reciprocal motion: An atomic force microscopy study.

نویسندگان

  • Yalpi Fatma
  • Uzun Ozgur
چکیده

AIM To evaluate the surface topography changes in three nickel-titanium (NiTi) file systems using either rotary or reciprocal motion using atomic force microscopy (AFM), and to determine the effect of scanning area on the AFM results in this study. METHODOLOGY Five points on a F2 Protaper file, R25 Reciproc file, and a Primary file from WaveOne systems were scanned preoperatively in 1 × 1 and 5 × 5 µm(2) with an AFM device that can scan an intact (not sectioned) file. One standardized resin block was used for each instrument, according to the manufacturer's recommendations. Points were re-scanned postoperatively using the same AFM and settings. Root-mean-square (RMS) and roughness average (Ra) values were obtained. The preoperative and postoperative surface topographies were compared separately in terms of RMS and Ra values. The surface topography change scores were analyzed using Kruskal-Wallis and Mann-Whitney U tests using a 0.10 significance level. RESULTS There were no significant differences preoperatively among the NiTi file systems in 1 × 1 or 5 × 5 µm(2) areas. Postoperatively, the WaveOne Primary had more surface irregularities (significant for 5 × 5 µm(2) scan in Ra evaluation). CONCLUSIONS Three-dimensional AFM images of instrument surfaces showed topographic irregularities preoperatively and postoperatively. AFM results differ depending on the scanning area and file used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Surface Characteristic Changes of WaveOne Gold and WaveOne Single Reciprocating Files Using Scanning Electron Microscopy: An in-vitro Study

Introduction: The purpose of this study was to evaluate surface topography of WaveOne Gold (WOG) and WaveOne (WO) files using SEM before and after use. Methods: Twelve primary files from each system were scanned for surface defects before instrumentation at 100x and 750x. Each file was planned ti be used to instrument six root canals and then examined under SEM after preparing one, three and six...

متن کامل

Surface Evaluation of Resin Zein Films Containing Sugar Plasticizers by Permeability and Atomic Force Microscopy Analysis

     Zein is one of the best biopolymer for edible film making and sugars are natural plasticizers for biopolymers. In this research, sugars (fructose, galactose and glucose) at three levels (0.5, 0.7, 1 g/g of zein) were used as plasticizers for zein protein films and their water vapor permeability (WVP), oxygen permeability (OP) and atomic force microscopy (AFM) topography were studied. The p...

متن کامل

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study)

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study) Dr. M.H. Zarrabi* - Dr. A. Talati** - Dr. S. Moradi** - Dr. L. Shakeri*** * - Associate Professor and Chief of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Scien...

متن کامل

Ultra structural characteristics of methicillin resistant Staphylococcus aureus cell wall after affecting with lytic bacteriophages using atomic force microscopy

Objective(s): During the last years with increasing resistant bacteria to the most antibiotics bacteriophages are suggested as appropriate treatment option. To investigate lytic activity of bacteriophages there are indirect microbial procedures and direct methods. The present study to complement microbial procedures and investigate ultra-structural characteristics of infection bacterium-phage u...

متن کامل

Effects of Fluoride on NiTi Orthodontic Archwires: An X-ray Diffraction Study

Objective: To explore the changes in nickel-titanium (NiTi) archwires after exposure to fluoride-containing acetic acid solutions. Materials and methods: Preformed rectangular NiTi wires were immersed in either an acidulated fluoride solution, a neutral fluoride solution or distilled water (control) for 1.5 hours at 37°C. After immersion, the unloading force values at four deflection points wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy research and technique

دوره 77 3  شماره 

صفحات  -

تاریخ انتشار 2014