Mathematical Framework for Fast and Rigorous Track Fit for the ZEUS Detector

نویسنده

  • Alexander Spiridonov
چکیده

In this note we present a mathematical framework for a rigorous approach to a common track fit for trackers located in the inner region of the ZEUS detector. The approach makes use of the Kalman filter and offers a rigorous treatment of magnetic field inhomogeneity, multiple scattering and energy loss. We describe mathematical details of the implementation of the Kalman filter technique with a reduced amount of computations for a cylindrical drift chamber, barrel and forward silicon strip detectors and a forward straw drift chamber. Options with homogeneous and inhomogeneous field are discussed. The fitting of tracks in one ZEUS event takes about of 20ms on standard PC. ∗E-mail: [email protected] Permanent address: Institute of Theoretical and Experimental Physics, 117259 Moscow, Russia 1

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Architecture of the ZEUS Micro Vertex Detector DAQ and Second Level Global Track Trigger

The architecture of the ZEUS Micro Vertex Detector data acquisition system and the implementation of its second level trigger, the ZEUS Global Track Trigger are described. Data from the vertex detectors HELIX read-out chips, corresponding to 200k channels, are digitized by 3 crates of ADCs which perform noise and pedestal subtraction, and data suppression and compaction. PowerPC VME board compu...

متن کامل

Design and calibration of a passive detector for separating neutron, proton and alpha particles in mixed radiation fields

In this study, calibration process was carried out for deigned new CR-39 nuclear track detector for protons, neutrons and alpha particles separately under the same etching condition. In order to aim this purpose, americium-beryllium standard source (241Am-Be) and Plexiglas phantom for neutron irradiation, brass collimators and americium standard source (241Am) for alpha irradiation and the acce...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

The Optical Alignment System of the ZEUS MicroVertex Detector

The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment system monitors the position of the vertex detector support structure with respect to the central tracking detector using semi-transparent amorphous-silicon ...

متن کامل

INTRODUCTION AND DEVELOPMENT OF SURROGATE MANAGEMENT FRAMEWORK FOR SOLVING OPTIMIZATION PROBLEMS

In this paper, we have outlined the surrogate management framework for optimization of expensive functions. An initial simple iterative method which we call the “Strawman” method illustrates how surrogates can be incorporated into optimization to stand in for the most expensive function. These ideas are made rigorous by incorporating them into the framework of pattern search methods. The SMF al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008